Laserfiche WebLink
'( ,aY' <br /> UNIFIED PROGRAM CONSOLIDATED FORM <br /> TANKS <br /> UNDERGROUND STORAGE TANKS- TANK PAGE 1 <br /> (Two pages per tank) <br /> Page 6 of 7 <br /> TYPE OF ACTION ❑ 1.NEW PERMIT ❑ 4.AMENDED PERMIT ® 5.CHANGE OF INFORMATION ❑ 6.TEMPORARY TANK CLOSURE 430. <br /> (Check one item only) ❑ 3.RENEWAL PERMIT ❑ 7.PERMANENTLY CLOSED ON SITE <br /> (Specify reason) (Specify reason) ❑ 8.TANK REMOVED <br /> BUSINESS NAME(Same asFACILITY NAME orDBA-Doing Business As) 3. FACILITY ID: 1. <br /> Rai Gas Stations,Inc.dba March Lane 76 <br /> LOCATION WITHIN SITE(Optional) 431. <br /> I.TANK DESCRIPTION <br /> (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# 432• TANK MANUFACTURER 433• COMPARTMENTALIZED TANK ❑Yes ® No 434. <br /> TA-0117508 XERXES If"Yes,"complete one page for each compartment. <br /> DATE INSTALLED 435. TANK CAPACITY IN GALLONS 436. NUMBER OF COMPARTMENTS 437 <br /> (YEAR/MO) <br /> 01/01/1991 9,728 1 <br /> ADDITIONAL DESCRIPTION(For local use only) 438. <br /> II.TANK CONTENTS <br /> TANK USE 439. PETROLEUM TYPE 440. <br /> ® 1. MOTOR VEHICLE FUEL ❑ la. REGULAR UNLEADED ❑2. LEADED ❑5. JET FUEL <br /> (If checked,complete Petroleum Type) ® lb. PREMIUM UNLEADED [13. DIESEL ❑6. AVIATION GAS <br /> ❑ 2. NON-FUEL PETROLEUM ❑lc. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER: <br /> ❑ 3. CHEMICAL PRODUCT COMMON NAME(from Hazardous Materials Inventory page) 441. CAS#(from Hazardous Materials Inventory page) 442. <br /> ❑ 4. HAZARDOUS WASTE Unleaded Gasoline 8006-61-9 <br /> (Includes Used Oil) <br /> ❑ 95.UNKNOWN <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ I. SINGLE WALL 0 3. SINGLE WALL WITH EXTERIOR D 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443. <br /> (Check one item only) MEMBRANE LINER ❑95.UNKNOWN <br /> ®2. DOUBLE WALL ❑4. SINGLE WALLIN A VAULT ❑99. OTHER <br /> TANK MATERIAL-primary tank ® 1. BARE STEEL 0 3. FIBERGLASS/PLASTIC C135. CONCRETE El 95.UNKNOWN 444. <br /> (Check one item only) ❑2. STAINLESS STEEL. ❑4. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPATIBLE ❑99.OTHER: <br /> REINFORCED PLASTICFRP W/100%METHANOL <br /> TANK MATERIAL-secondary tank 1. BARE STEEL ®3. FIBERGLASS/PLASTIC <br /> U 8. FRP COMPTIBLE W/100%METHANOL El 95.UNKNOWN 445. <br /> (Check one item only) ❑2. STAINLESS STEEL❑4. STEEL CLAD W/FIBERGLASS [19. FRP NON-CORRODABLE JACKET ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) ❑ 10. COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING U 1.RUBBER LINED 3.EPDXY LINING C 5.GLASS LINING L1 95.UNKNOWN 446. DATE INSTALLED 447. <br /> OR COATING ❑2.ALKYD LINING ❑4.PHENOLIC LINING ®6.UNLINED ❑99.OTHER <br /> Check one item only) <br /> OTHER CORROSION El I.MANUFACTURED CATHODIC 0 3.FIBERGLASS REINFORCED PLASTIC 095.UNKNOWN 448. DATE INSTALLED 449. <br /> PROTECTION PROTECTION ❑4.IMPRESSED CURRENT ❑99.OTHER <br /> IfA licable) ❑2.SACRIFICIAL ANODE <br /> SPILL AND OVERFILL YEAR INSTALLED 450. TYPE 451. OVERFILL PROTECTION EQUIPMENT: YEAR INSTALLED 452. <br /> (Check all that apply) ®1.SPILL CONTAINMENT 2003 ❑1.ALARM _®3.FILL TUBE SHUT OFF VALVE <br /> ®2.DROP TUBE 2003 ❑2.BALL FLOAT_❑4.EXEMPT <br /> ®3.STRIKER PLATE 1998 <br /> IV.TANK LEAK DETECTION <br /> (A description ofthe monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK 453. IF DOUBLE WALL TANK OR TANK WITH BLADDER 454. <br /> (Check all that apply) (Check one item only) <br /> ❑1.VISUAL(EXPOSED PORTION ONLY) ❑5.MANUAL TANK GAUGING(MTG) ❑1.VISUAL(SINGLE WALL INVAULT ONLY) <br /> ❑2.AUTOMATIC TANK GAUGING(ATG) ❑6.VADOSE ZONE ®2.CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3.CONTINUOUS ATG ❑7.GROUNDWATER ❑3.MANUAL MONITORING <br /> ❑4. STATISTICAL INVENTORY RECONCILIATION ❑8.TANK TESTING <br /> (SIR)+BIENNIAL TANK TESTING ❑99.OTHER <br /> V.TANK CLOSURE INFORMATION/ PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455. ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456. TANK FILLED WITH INERT MATERIAL? 457. <br /> gallons ❑Yes ❑ No <br /> UPCF hwfwrc-b(1/99)-1/4 www.unidocs.org Rev.02/16/00 <br />