My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LODI
>
2500
>
2300 - Underground Storage Tank Program
>
PR0231356
>
COMPLIANCE INFO_2016-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2022 10:55:27 AM
Creation date
11/8/2018 9:36:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2018
RECORD_ID
PR0231356
PE
2361
FACILITY_ID
FA0003815
FACILITY_NAME
TESORO (MOBIL) 68154
STREET_NUMBER
2500
Direction
W
STREET_NAME
LODI
STREET_TYPE
AVE
City
LODI
Zip
95240
APN
02740006
CURRENT_STATUS
01
SITE_LOCATION
2500 W LODI AVE
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\L\LODI\2500\PR0231356\COMPLIANCE INFO.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
283
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Veeder-Root Line Leak ApplicaTion Guide • <br /> TLS-450 Series Consoles Hardware Required for DPLLD Leak Detection <br /> Digital Pressurized Line Leak Detector (DPLLD) -Order one per line. <br /> MODEL <br /> 859080-001 PRESSURIZED LINE LEAK DETECTOR WITHOUT SWIFTCHECK VALVE <br /> 859080-002 PRESSURIZED LINE LEAK DETECTOR WITH SWIFTCHECK VALVE <br /> Modules <br /> • One Universal Sensor Module is required per console.One USM module monitors up to 16 lines. <br /> • One Input/Output Module is required per console.One 1/0 module monitors up to 5 lines. <br /> MODEL <br /> 332812-001 UNIVERSAL SENSOR MODULE <br /> 332813-001 INPUT/OUTPUT MODULE <br /> TLS-350 Hardware Required for PLLD Leak Detection <br /> Pressurized Line Leak Detector (PLLD) <br /> Order one per line. <br /> MODEL <br /> 848480-003 PRESSURIZED LINE LEAK DETECTOR WITH SWIFTCHECK VALVE <br /> 848480-001 PRESSURIZED LINE LEAK DETECTOR WITHOUT SWIFTCHECK VALVE <br /> PLLD Modules <br /> •TLS-350/TLS-350 Plus/rLS-350R Consoles-Leak Detection for up to 6 Lines <br /> One Pressurized Line Leak Detector Interface Module is required per console.Order PLLD Controller modules as required <br /> -one Controller module monitors up to 3 lines. <br /> MODEL <br /> 330843-001 SIX INPUT PRESSURIZED LINE LEAK INTERFACE MODULE(MAXIMUM i PER CONSOLE) <br /> 330374-001 PRESSURIZED LINE LEAK CONTROLLER MODULE(MAXIMUM 2 PER CONSOLE) <br /> -TLS-350J Consoles-Leak Detection for up to 4 Lines <br /> One'S PLLD Interface Module is required per console.Order PLLD Controller modules as required-one Controller module <br /> monitors up to 3lines. <br /> MODEL <br /> 330843-002 'J'PLLD INTERFACE MODULE (MAXIMUM 1 PER CONSOLE) <br /> 330374-001 PRESSURIZED LINE LEAK CONTROLLER MODULE(MAXIMUM 2 PER CONSOLE) <br /> PLLD Precision Testing Software Module <br /> Precision line leak detection capability(0.2 gph/0.1 gph) requires one SEM(Software Enhancement Module)for the console <br /> that must be ordered separately from the table below.Not required for 3.0 gph-only line leak detection capability. <br /> r • <br /> OPTIONTLS-350PLUS/TLS-35OR WITH BIR <br /> WITHOUT BIR (SEM P/N) <br /> TESTING <br /> ULTIMATE TESTING 330160-010 330160-110 <br /> RISKMANAGEMENT 330160-060 330160-160 <br /> BASE COMPLIANCE 330160-050 330160-150 <br /> 3.0 GPH INCLUDED' INCLUDED* <br /> •A SEM is not required for 3 GPH-only testing. <br /> 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.