My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1490
>
2300 - Underground Storage Tank Program
>
PR0541436
>
INSTALL 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/22/2020 1:59:23 PM
Creation date
11/8/2018 9:40:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2018
RECORD_ID
PR0541436
PE
2351
FACILITY_ID
FA0023750
FACILITY_NAME
AGS FUEL INC DBA CIRCLE K CHEVRON
STREET_NUMBER
1490
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1490 S MAIN ST
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\M\MAIN\1490\PR0541436\2018 INSTALL.PDF
QuestysFileName
2018 INSTALL
QuestysRecordDate
5/2/2018 6:57:48 PM
QuestysRecordID
3878462
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
501
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Veeder-Root Line Leak Application Guide <br /> Check Valve Requirements <br /> DPLLD,PLLD and WPLLD require certain check valves or Pressurstat assemblies to be installed on the pump. Use of non-com- <br /> patible check valves can result in loss of leak detection performance. <br /> 3.0 GPN Only 3.0,0.2,0.1 GPN Additional Req'd.Parts for Man--rfolded <br /> Supported Testing Testing Lines(Single Tank w/2 STPs,or 2 or <br /> Pumps Check/He let Valve Type (peq'd.Klt) (Req'd.qt) More Tanks w/STP in Each) <br /> DPLLD/PLLD Applications - <br /> The Red Jacket None Required 848480-001(TLS-350) 848480-001(TL$-350) Check Valve for Each Slave Pump P/N 410153-002 <br /> 859080-0010 LS-4XX) 859080-001(RS-4XX) (See illustration in Nate 1 below) <br /> Quantum(All Models) Red Jacket SpikeCheck Valve(Factory 848480-001(TLS-350) 848480-001(TL.S-350) Red Jacket Quantum SpikeCheck Valve,Non-PSI <br /> (See Note 2 below) Installed) 859080-001(ILS-4XX) 859080-001(TLS-4XX) Relief Valve,Required for Each Slave Pump,P/N 388- <br /> Red Jacket SpikeCheck Valve(Field Only 848480-001(TL.S-350) 848480-001 OLS-350) 081-5(Field Installed Only) <br /> Installed)P/N 388-080-5 859080-001(TLS-4XX) 859080-001(TLS-4XX) <br /> Red Jacket Pressurstat Assembly. 848480-001(TLS-350) --Not supported— Non-Vented SwiftCheck Valve for Each Slave Pump <br /> 859080-001(TLS-0XX) kit.P/N 330020-416 <br /> SwiftCheck 648480-003(TLS-350) 848480-003(TLS-350) <br /> 859080-002(11SAM) 859080-002(rLS-0XX) <br /> Standard(All Models) SwiftCheck 848480-003(TLS-350) 848480-003(TLS-350) Non-Vented SwiftCheck Valve for Each Slave Pump <br /> 859080-002(TLS-0XX) 859080-002(rLS-4XX) kit,P/N 330020-416 <br /> Red Jacket Functional Element Assembly 848480-001(TLS-350) ---Not supported— <br /> 859080-001(TLS-4XX) <br /> Red Jacket SpikeCheck Valve(Field 848480-001(TLS-350) 848480-001(TLS-350) Red Jacket Standard SpikeCheck Valve,Non-PSI <br /> Installed Only)P/N 410557-001 859080-00101-S-0XX) 859080-001(TLS-4XX) Relief Valve,Required for Each Slave Pump,P/N <br /> 410557-002(Field Installed Only) <br /> Maxxum None Required 848480-001(fLS-350) 848480-001(TLS-350) See Note 4 below. <br /> Big-Flo Pressurstat Kit P/N 144-314-5 859080-001(TLS-4XX) 859080-001(TLSAXX) <br /> (See Note 3 below) <br /> FE Petro FE Petra Model R P/N 400988932 and 848480-001(TLS-350) 848480-001(TLS-350) Non-Vented SwiftCheck Valve for Each Slave Pump <br /> Replacement O-ring for the Valve Housing 859080-001(TLS-4XX) 859080-001(TLS-0XX) <br /> (See Note 4 below) kit, P/N 330020-416 ----OR---- <br /> FE Petro 65 psi Relief Check Valve(FE P/N <br /> FE Petro Model R Relief Valve P/N <br /> 401330902 402459931)(See Note 5 below) <br /> Tokheim&Bennett SwiftCheck 848480-003(TLS-350) 848480-003(TLS-350) Non-Vented SwiftCheck Valve for Each Slave Pump <br /> 859060-002(ILS-4XX) 859080-002(TLS-0XX) kit,P/N 330020-016 <br /> WPLLD Applications <br /> The Red Jacket None Required 849490-006 849490-006 High Pressure Check Valve for Each Slave Pump,P/N <br /> 410153-002(See illustration in Note 1 below) <br /> Quantum(All Models) Red Jacket SpikeCheck Valve(Factory 849490-005 849490-005 Non-Vented SwiftCheck Valve for Each Slave Pump <br /> (See Note 2 below) Installed) (Except CPT) (Except CPT) kit,P/N 330020-016 <br /> Red Jacket Pressurstat Assembly 849490-005 Not supported <br /> (ExceptCPT) <br /> Standard(All Models) SwiftCheck 849490-002 849490-002 <br /> (Except CPT) (Except CPT) <br /> Red Jacket Functional Element Assembly 849490-003 —Notsupported— <br /> (Except CPT) <br /> FE Petro FE Petro Model R P/N 400988932 and 849490-001 849490-001 Nan-Vented SwiftCheck Valve for Each Slave Pump <br /> Replacement O-ring for the Valve Housing kit, P/N 330020A16 —OR— <br /> (See Note 5 below) FE Petro 65 psi Relief Check Valve(FE P/N <br /> 402459931)(See Nate 5 below) <br /> NOTES: <br /> 1. The Veeder-Root High Pressure Check Valve(P/N 410153-002)is 2. For Red Jacket Quantum pumps,the SpikeCheck is the preferred check valve type. <br /> shown below: <br /> 3. 0.2/0.1 gph testing is supported for the Maxxum pump,but you must select'User <br /> Defined'as the pipe type during DPLLD or PLLD setup. <br /> a 4. If maximum pump pressure is NOT a minimum of 5 psi below the pressurstat relief <br /> O setting,then a check valve must be installed in the discharge line of the slave pump(see <br /> "Manifolded Line Applications"on page 12). <br /> High pressure relief valva has H 5. Veeder-Root does not warrant the performance of FE Petro's Model'R'check valve or 65 <br /> 'H'stemped on underside or <br /> poppet verve psi relief check valve. <br /> 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.