My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1490
>
2300 - Underground Storage Tank Program
>
PR0541436
>
INSTALL 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/22/2020 1:59:23 PM
Creation date
11/8/2018 9:40:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2018
RECORD_ID
PR0541436
PE
2351
FACILITY_ID
FA0023750
FACILITY_NAME
AGS FUEL INC DBA CIRCLE K CHEVRON
STREET_NUMBER
1490
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1490 S MAIN ST
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\M\MAIN\1490\PR0541436\2018 INSTALL.PDF
QuestysFileName
2018 INSTALL
QuestysRecordDate
5/2/2018 6:57:48 PM
QuestysRecordID
3878462
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
501
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Veeder-Root Line Leak Application Guide <br /> Special Installations <br /> Manifolded Line Applications <br /> DPLLD, PLLD and WPLLD leak detection systems can handle product lines supplied by multiple tanks and pumps,to a maxi- <br /> mum of 8 tanks and pumps per product line. <br /> Standard line leak sensing and check valve equipment should be installed at the primary pump. <br /> To perform 0.2 and 0.1 gph tests,a non-vented SwiftCheck valve(P/N 330020-416),or new Red Jacket 65 psi relief valve(P/N <br /> 410153-002),or SpikeCheck Valve Non-PSI Relief Valve for Standard Pump(P/N 410557-002), or FE Petro 65 psi Relief Check <br /> Valve(FE P/N 402459931)should be installed on each of the other pumps supporting the manifolded product line.The Non- <br /> Vented SwiftCheck Valve is rated to a maximum 70 gpm. <br /> For 5 HP Maxxum pumps in diesel,an additional in-line check valve with no pressure relief should be <br /> installed on the'Slave'pump to prevent backflow. <br /> A relay on a Four-Relay module or 1/0 Combination module(TLS-350 Series)or 1/0 Module(TLS-450 Series)must be available <br /> to control each secondary pump.The standard line leak modules will provide pump control output for the primary pump and the <br /> "Pump In"signal for the set. <br /> A typical manifolded line installation for DPLLD and PLLD is shown below: <br /> To Dispensers <br /> Flexible Pipe with 1 Flexible Pipe with <br /> Swivel or Union Swivel or Union <br /> DPLLD or PLLD Sensor Ball Valve Ball Valve Non-Vented <br /> SwiftCheck Valve SwiftCheck <br /> Valve(if req'd.) <br /> Assembly <br /> a <br /> Warning Tag Master Pump Slave Pump <br /> plgMM ks,eps Lower Numbered Tank Higher Numbered Tank <br /> Transducer Installation - Red Jacket CPT and Quantum CPT Pumps <br /> This installation procedure is to be used with Red Jacket CPT and Quantum CPT Pumps. <br /> 1. Install the Red Jacket CPT Transducer Adapter Kit(Red Jacket part number 144-326-5)following the instructions with the <br /> kit.Thread the PLLD transducer in the mechanical LLD port of the pump. <br /> Seal any pipe threads using a UL-classified, nontoxic pipe sealant suitable for the fuel involved. <br /> The figure below illustrates two DPLLD and PLLD transducer installations in Red Jacket CPT pumps-consult"Check Valve <br /> Requirements"on page 6,to determine what check valve you will need to install to perform your intended level of testing. <br /> 2. Verify that the TLS-350 Series Console has Version x19 or later(TLS-450 Series Console has Version 1 or later)software. <br /> 3. Verify that the CPT Controller has Version 1.02 or later software installed. <br /> 12 <br />