My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1490
>
2300 - Underground Storage Tank Program
>
PR0541436
>
INSTALL 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/22/2020 1:59:23 PM
Creation date
11/8/2018 9:40:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2018
RECORD_ID
PR0541436
PE
2351
FACILITY_ID
FA0023750
FACILITY_NAME
AGS FUEL INC DBA CIRCLE K CHEVRON
STREET_NUMBER
1490
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1490 S MAIN ST
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\M\MAIN\1490\PR0541436\2018 INSTALL.PDF
QuestysFileName
2018 INSTALL
QuestysRecordDate
5/2/2018 6:57:48 PM
QuestysRecordID
3878462
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
501
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Veeder-Root Line Leak Application Guide <br /> 4. Locate red switch bank labeled S1 on the CPT's Controller CPU board,and verity that dip switch 2 is set to the Closed <br /> position (to enable the PLLD precision line leak function),and dip switch 8 is set to the Open position(to disable the CPT's <br /> line leak function). <br /> 5. Verify that the Rotary Pressure Dial,also on the CPT's Controller CPU board, is set to either the 2(24 psi),3(27 psi),4(30 <br /> psi),5(33 psi), or 6(36 psi)position. <br /> �` onawrona ew <br /> O O 1 <br /> t <br /> Tv ��� T LT w _ <br /> I DPLLD or PLLD <br /> transducer <br /> Only 'I <br /> DPLLD or PLLD O <br /> transducer <br /> in SwiftCheck <br /> O (0 O Valve ® :(0) SpikeCheck <br /> Valve Assy. <br /> O Functional O <br /> Element <br /> Red Jacket Standard CPT Red Jacket Quantum CPT <br /> Transducer Installation - Red Jacket Big-Flo Pumps, Red Jacket Maxxum Pumps and FE Petro <br /> High Capacity Pumps <br /> BIG-FLO PUMPS <br /> 1. You will need to install a reducing tee(customer supplied)in either of the 3-inch discharge ports of the pump with the 2- <br /> inch opening facing up. If you have the room,it may be easier to install this tee between the Pressurstat kit and the unused <br /> port instead of in the discharge line(as shown in the figure below).Alternatively,the DPLLD or PLLD transducer can be <br /> installed in the leak detector port of a Big-Flo leak detector if it is already present in the line(as shown in the figure below). <br /> 2. Install the Red Jacket Big-Flo Pressurstat Kit(Red Jacket part number 144-314-5)following the instructions with the kit. <br /> 3. Thread the DPLLD or PLLD transducer into the 2-inch opening of the tee. <br /> Seal any pipe threads using a UL-classified, nontoxic pipe sealant suitable for the fuel involved. <br /> 4. Verify that the TLS-350 Series Console has Version x19 or later(TLS-450 Series Console has Version 1 or later)software. <br /> Junction box <br /> OPTIONAL INSTALLATION FXAMPLE (customer supplied) <br /> f.P 'r ,' y.f <br /> 3/4'NPT Union, °' - 4 't, . 'a <br /> 3/4'NPT nipples, DPLLD or PLLD transducer <br /> reducing nipple / 3"discharge line Seal-off,epoxy seal per NFPA <br /> (customer supplied) 1 (to dispensers) spec(customer supplied) <br /> conduit to console <br /> (customer supplied) <br /> DPLLD or PLLD transducer in 2'port <br /> r} of Big-Flo Leek Detector(customer <br /> �upplied) <br /> Red Jacket Big-Flo 3'x 3'90 degree elbow <br /> Red Jacket Big-Flo Pressurstat kit- (customer supplied) <br /> Pressurstat kit- 2"x 2'x 3"reducing tee P/N 144-314-5 <br /> PM 144-314-5 and 3'NPT nipple (customer supplied) 3"discharge line(to dispensers) <br /> (customer supplied) (customer supplied) <br /> 13 <br />
The URL can be used to link to this page
Your browser does not support the video tag.