FACILITY_NAME
CENTRAL GAS STOCKTON
STREET_NUMBER
3440
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
STOCKTON
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3440 E MAIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MAIN\3440\PR0231173\COMPLIANCE INFO 2013 - 2015.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
167
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
`r San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www.sigov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> UNITED GAS 3440 E MAIN ST. STOCKTON Junt <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 207 CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> There were no designated monthly inspection reports and training documents provided at the time of inspection for <br /> review. During the monthly inspection, the designated operator shall do the following: <br /> 1. Review the alarm history for the previous month, check that each alarm was documented and responded to <br /> appropriately, and attach a copy of the alarm history with documentation taken in response to any alarms to the <br /> monthly report. <br /> 2.Visually inspect all spill containers and UDC sumps, and any tank top sump that had an alarm for which there is no <br /> record of a service visit. <br /> 3.Check that all required testing and maintenance for the UST system have been completed and document the dates <br /> they were done. <br /> 4. Verify that all employees have been trained during the monthly inspection. <br /> Ensure that designated operators performing monthly inspections at this facility are including all of the required <br /> information on the reports, inspecting all the required areas and training all employee. <br /> This is a minor violation. <br /> 208 CCR 2715 Designated operator monthly inspection reports not maintained on site for at least 12 months. <br /> Since the change of ownership on May 26, 2015 there were no designated operator monthly inspection reports were <br /> not found on site. Designated operator monthly inspection reports for the previous twelve months shall be retained on <br /> site. Locate and ensure that copies of the previous twelve months of designated operator monthly inspection reports <br /> are maintained on site. Submit copies to the EHD. <br /> This is a minor violation. <br /> 209 CCR 2715(f) Designated operator employee training not performed or log not kept. <br /> Since the change of ownership on May 26, 2015, the designated operator employee training was not performed. The <br /> designated operator shall train facility employees for which he or she is responsible in the proper operation and <br /> maintenance of the UST system once every 12 months. The training shall include, but is not limited to: <br /> 1. Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br /> 4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br /> Ensure that employees have been trained by the designated operator, maintain the list on site, and submit a copy of <br /> the training records to the EHD. <br /> This is a minor violation. <br /> Received by Inspector: Phone: Date: <br /> (initial): A-S CINDY VO, EH Specialist (209) 468-8257 06/29/2015 <br /> Page 5 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.