Laserfiche WebLink
San Joaquin County 1 <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209) 468-3433 Web:www.sjgov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> UNITED GAS 3440 E MAIN ST STOCKTON June 29, 2015 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 309 CCR 2636(f)(1) Monitoring in the UDCs failed to activate an audible and visual alarm or stop the flow at the UDC. <br /> The Bravo box float and chain in the UDC 1/2: float chain closest to 89 and 91 piping, 3/4:float and chain closest to 87 <br /> and 89 piping, 5/6: float and chain closest to 87 and 89 piping and 7/8: float and chain closest to 87,89, and 91 piping <br /> sump failed to stop the flow of product at the dispenser when tested. All monitoring equipment shall be maintained to <br /> activate an audible and visual alarm or stop the flow of product at the dispenser when it detects a leak. The service <br /> technician adjusted the chain(s) and verified functionality. This was corrected on site. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by July 29, 2015. <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br /> Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received By Received By(printed name and title): Date: <br /> (signature): A�a'-� J� Jaspal Singh, Manager e - 9 9 a C'tg— <br /> Inspector Inspector(printed name and title): Inspector Phone: <br /> (signature): CINDY VO, EH Specialist (209) 468-8257 <br /> Page 6 of 6 <br />