My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
3440
>
2300 - Underground Storage Tank Program
>
PR0231173
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:39:03 PM
Creation date
11/8/2018 9:41:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0231173
PE
2361
FACILITY_ID
FA0006423
FACILITY_NAME
CENTRAL GAS STOCKTON
STREET_NUMBER
3440
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
STOCKTON
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3440 E MAIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MAIN\3440\PR0231173\COMPLIANCE INFO.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
110
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN Environmental Health Department <br /> civ —COUNTY— <br /> ,.- <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> UNITED GAS (925)914-0873 February 02, 2018 <br /> Facility Address: CERS ID: <br /> 3440 E MAIN ST, STOCKTON, CA 95205 10182099 <br /> Inspection Contact: Title: Phone: <br /> Manpreet Singh Owner (925)914-0873 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION-Operating Permit 2361 -UST FACILITY <br /> Consent For: Consent Given By: <br /> O Inspection Z Photos O Samples Manpreet Singh, Owner <br /> Service Technician Onsite: Exp.Date: Designated Operator. Exp.Date: <br /> David Wrinkler 01/29/2020 David Tumer 07/07/2019 <br /> Service Technician Manufacturer's Training: <br /> Veeder Root, 02/03/18;VMI, 11/15/19; Tank Tester, 03/31/20 <br /> CCR-California Code of Regulations HSC=Health and Safety Code CFR=Code of Federal Regulations <br /> V=Vialation R=Repeat violation COS-Connected an site during inspection <br /> File Review <br /> 101 HSC 25284 Failure to obtain a valid permit to operate from the EHD including but not limited to unpaid fees o V o R o COS <br /> 102 HSC 25284(a)(3)(A)/(B) No written agreement between tank owner and tank operator to monitor the tank system o V in R o COS <br /> 103 HSC 25292.2,25299.30 Current financial responsibility documents not submitted •V is R a COS <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current o V o R c COS <br /> 105 CCR 2632(d)(1), Failed to have an approved UST monitoring plan u V o R in COS <br /> 2634(d) <br /> 106 CCR 2632(4)(2), Failed to have an approved UST response plan o V in R o COS <br /> 2634(e) <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed •V a R o COS <br /> 108 CCR 2637(f),2638(e) Failed to notify the EHD 48 hours prior to conducting testing o V o R o COS <br /> 109 CCR 2637 Failed to test secondary containment o V o R o COS <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days o V o R o COS <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually in V o R o COS <br /> 112 HSC 25284.2 Failed to test spill containers annually o V in R o COS <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days n V o R o COS <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down o V o R o COS <br /> 115 CCR 2715(a) Failed to submit to EHD notification of designated operator identification or change vein 30 days as V o R o COS <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC certification o V o R in COS <br /> 117 CCR 2663(h) Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after o V o R in COS <br /> 118 CCR 2663 Failed to submit tank lining certification within 30 days or to Conduct proper tests o V o R o COS <br /> 119 HSC 25299(a)(8), Documents were falsified or misrepresented o V in R o COS <br /> 25299(b)(7) <br /> 120 CCR 2635(d) Failed to submit UST Certification of Installation/Modification o V o R o COS <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report o V o R o COS <br /> 122 CCR 26316) Failure to submit and maintain UST system component statement of compatibility for substance stored 'V u R o COS <br /> On Site Records <br /> 201 CCR 2712(b) Failure to maintain monitoring,maintenance,and follow up action records u V n R o COS <br /> FA0006423 PR0231173 SCO01 02/0212018 <br /> EHD 23 01 Rev.1013112017 Page 1 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, Califomia 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.