My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
3440
>
2300 - Underground Storage Tank Program
>
PR0231173
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:39:03 PM
Creation date
11/8/2018 9:41:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0231173
PE
2361
FACILITY_ID
FA0006423
FACILITY_NAME
CENTRAL GAS STOCKTON
STREET_NUMBER
3440
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
STOCKTON
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3440 E MAIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MAIN\3440\PR0231173\COMPLIANCE INFO.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
110
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J O A Q U I N Environmental Health Department <br /> —COUNTY— <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> UNITED GAS 3440 E MAIN ST, STOCKTON February 02, 2018 <br /> On Site Records <br /> 202 CCR 2712(b) Failed to maintain cathodic protection test records on site for at least 6 1/2 years o V o R o COS <br /> 203 CCR 2712(b) Failure to maintain records of repairs,lining,and upgrades on site,for the life of the UST o V o R in COS <br /> 204 CCR 2712(i) Current monitoring plan approved by the EHD not found on site o V in R o COS <br /> 205 CCR 2712(1),2634(e) Failure to submit a current UST Response Plan and have it available onsite o V in R o COS <br /> 206 CCR 2712 Failure to comply with UST operating permit conditions <br /> m o oCOS <br /> 207 HSC 25294 Failed to record unauthorized release from primary containment o V o R o COS <br /> 208 CCR 2650(e),2652 Failed to notify the EHD of a reportable unauthorized release o V o R o COS <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed o V o R o COS <br /> 210 CCR 2715(e) Designated operator monthly inspection reports not maintained on site for at least 12 months o V o R o COS <br /> 211 CCR 2715(f)(2) Designated operator employee training not performed or log not kept .V o R o COS <br /> 212 CCR 2715(f)(2) Unstaffed facility failed to have or implement a training program approved by the EHD o V o R o COS <br /> 213 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept o V c R in COS <br /> 214 HSC 25281.5(b)(3) Unburied emergency generator fuel piping not visually inspected at least monthly or log kept o V o R o COS <br /> 215 CCR 2712(i) Failure to retain a copy of the permit to operate at the facility o V o R in COS <br /> UST System Observations <br /> 301 HSC 25292.1 UST system is not operated to prevent unauthorized release,including spills and overfills o V o R o COS <br /> 302 HSC 25291(b) UST system incapable of detecting leak from primary into secondary containment(pre-Jul 2003) o V o R o COS <br /> 303 HSC 25280.2(d) Monitoring system not maintained to detect entry into secondary containment(Jul 2003-Jun 2004) o V o R o COS <br /> 304 HSC 25290.1(d) Monitoring system not maintained to detect entry into secondary containment(after Jul 2004) o V o R o COS <br /> 305 HSC 25290.1(e) VPH monitoring of the interstitial spaces of the UST system is not maintained o V n R o COS <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak atthe earliest opportunity o V in R o COS <br /> 307 CCR 2631(g),2632(c) Monitoring system of the interstitial space of a double walled system not maintained .V .R .COS <br /> 308 CCR 2636(f) Failed to maintain a continuous monitoring system that activates an audible and visual alarm o V o R o COS <br /> 309 CCR 2636(0(1) Monitoring in sump/UDC failed to activate an audible and visual alarm or stop the flow product .V •R .COS <br /> 310 CCR 2636(f)(5) Failure to meet monitoring requirements in lieu of annual line tightness test o V o R o COS <br /> 311 CCR 2638(a),2641() Failed to properly program or operate leak detection equipment u V o R o COS <br /> 312 CCR 2638(f),2641(i) Failed to affix a tag sticker on monitoring equipment certified,repaired,or replaced o V o R o COS <br /> 313 HSC 25290.1,25290.2, Failure to construct,operate,and maintain primary containment as product-tight o V u R o COS <br /> 25291 <br /> 314 HSC 25290.1,25290.2, Failed to have secondary containment or secondary containment not tight o V o R o COS <br /> 25291 <br /> 315 HSC 25291(a) Water in secondary containment not removed,analyzed,and properly disposed of(preJul 2003) o V o R u COS <br /> 316 HSC 25290.1(c3), Secondary containment not constructed to prevent water intrusion(after Jul 2003) c V o R in COS <br /> 25290.2(c3) <br /> r318 <br /> 17 CCR 2636(f)(2) Line leak detector not installed do V o R o COS <br /> CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi .V o R .COS <br /> FA0005423 PRO231173 SC001 02/02/2018 <br /> EHD 23-01 Rev.1013112017 Page 2 of 6 Underground Storage Tank Program OR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sicehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.