My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1985-1999
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
470
>
2300 - Underground Storage Tank Program
>
PR0231441
>
COMPLIANCE INFO 1985-1999
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2022 11:30:00 AM
Creation date
11/8/2018 9:41:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985-1999
RECORD_ID
PR0231441
PE
2361
FACILITY_ID
FA0003604
FACILITY_NAME
BEACON STATION #3492*
STREET_NUMBER
470
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
22307101
CURRENT_STATUS
02
SITE_LOCATION
470 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MAIN\470\PR0231441\COMPLIANCE INFO 1985-1999.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
203
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
This requirement must be met in order to continue use of the <br /> underground storage tank. The owner of the underground storage <br /> system will be required to make upgrades in order to meet 1998 <br /> upgrade requirments . This Department requires that all sites that <br /> plan to use single wall fiberglass tanks, lined tanks or a lining <br /> process to meet 1998 upgrade requirements have a site assessment <br /> conducted. The site assessment must be conducted in accordance <br /> with PHS-EHD Policy number 96-004 (copy provided) . If <br /> contamination is encountered during the site assessment it will <br /> be considered an unauthorized release and Health and Safety Code <br /> Section 25296 (c) may apply. Section 25296 allows PHS-EHD to <br /> require the installation of a continuous onitored monitoring <br /> well . The requirement for a continuousl ztored monitoring <br /> well may be waived if the tank system i e d with a <br /> continuous monitoring system that meets c 3 <br /> standards . The tanks must be equiped with s fill <br /> protection in accordance with Title 23 CCR Sec on 5 (provided <br /> below) . <br /> 523-2665. Spill and Overfill Prevention Equipment Upgrade Requirements. <br /> By December 22, 1998, all underground storage tank systems shall be retrofitted with an <br /> overfill prevention system and a spill container which meet the requirements of section <br /> 2635(b). The local agency may waive the requirements for overfill prevention equipment if <br /> the conditions specified in section 2635(b) (3) are met. <br /> 523-2635. Installation and Testing Requirements for All New Underground Storage Tanks. <br /> (b) All underground storage tanks shall be equipped with a spill container and an <br /> overfill prevention system as follows: <br /> (1) The spill container shall collect any hazardous substances spilled during product <br /> delivery operations to prevent the hazardous substance from entering the subsurface <br /> environment. The spill container shall meet the following requirements: <br /> (A) If it is made of metal, the exterior wall shall be protected from galvanic <br /> corrosion. <br /> (e) It shall have a minimum capacity of five gallons (19 liters) . <br /> (C) It shall have a drain valve which allows drainage of the collected spill into <br /> the primary container or provide a means to keep the spill container empty. <br /> (2) The overfill prevention system shall not allow for manual override and shall meet one <br /> of the following requirements: <br /> (A) Alert the transfer operator when the tank is 90 percent full by restricting <br /> the flow into the tank or triggering an audible and visual alarm; or <br /> (B) Restrict delivery of flow to the tank at least 30 minutes before the tank <br /> overfills, provided the restriction occurs when the tank is filled to no more than <br /> 95 percent of capacity; and activate an audible alarm at least five minutes before <br /> the tank overfills; or <br /> (C) Provide positive shut-off of flow to the tank when the tank is filled to no <br /> more than 95 percent of capacity; or, <br /> located onethestopvofshut-off of the tank arelow to exposedht tank <br /> poductthat <br /> due tonone <br /> fittings <br /> overfilling. <br /> (3) The local agency may waive the requirement for overfill prevention equipment where the <br /> tank inlet <br /> ill <br /> overfill, andithe tank system islfilled bythe <br /> transferscontainer <br /> mores thang25tgallonsate to collect <br /> any <br /> one <br /> time. <br /> The piping system will require upgrading if it is constructed of <br /> single wall steel and was not cathodically protected from the <br /> point of its original installation. The piping must be upgraded <br /> to meet Title 23 CCR Section 2666 (provided below) . <br /> (a) By December 22, 1998, all underground piping containing hazardous substances other <br /> than motor vehicle fuel shall be retrofitted with secondary containment meeting the <br /> requirements of section 2636. <br />
The URL can be used to link to this page
Your browser does not support the video tag.