My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2011 - 2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
1206
>
2300 - Underground Storage Tank Program
>
PR0231175
>
COMPLIANCE INFO 2011 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2023 4:54:06 PM
Creation date
11/8/2018 9:42:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011 - 2017
RECORD_ID
PR0231175
PE
2361
FACILITY_ID
FA0001247
FACILITY_NAME
DP & DK Investments, Inc.
STREET_NUMBER
1206
Direction
E
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95210
CURRENT_STATUS
01
SITE_LOCATION
1206 E MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MARCH\1206\PR0231175\COMPLIANCE INFO 2011 - 2017.PDF
QuestysFileName
COMPLIANCE INFO 2011 - 2017
QuestysRecordDate
4/9/2018 3:51:45 PM
QuestysRecordID
3847565
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
321
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
F.In-Tank Gauging/SIR Equipment: r Check this box if tank gauging is used only for inventory control. <br /> r Check this box if no tank gauging or SIR equipment is installed. <br /> This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. <br /> Complete the following checklist: <br /> + Yes ' No* Has all input wiring been inspected for proper entry and termination, including testing for ground faults? <br /> + Yes C' No* Were all tank gauging probes visually inspected for damage and residue buildup? <br /> + Yes �' No* Was accuracy of system product level readings tested? <br /> + Yes r No* Was accuracy of system water level readings tested? <br /> • Yes l� No* Were all probes reinstalled properly? <br /> + Yes r No* Were all items on the equipment manufacturer's maintenance checklist completed? <br /> *In the Section H, below,describe how and when these deficiencies were or will be corrected. <br /> G.Line Leak Detectors(LLD): r Check this box if LLDs are not installed. <br /> ENVIRONMENTAL HEALTH <br /> Complete the following checklist: nF.PART ENT <br /> + Yes �' No* For equipment start-up or annual equipment certification,was a leak simulated to verify LLD performance?(Check all that <br /> C` N/A apply)Simulated leak rate:P 3 g.p.h.; r 0.1 g.p.h; r 0.2 g.p.h. <br /> + Yes ' No* Were all LLDs confirmed operational and accurate within regulatory requirements? <br /> + Yes No* Was the testing apparatus properly calibrated? <br /> * Yes (" No* For mechanical LLDs,does the LLD restrict product flow if it detects a leak? <br /> C' N/A <br /> Yes No* For electronic LLDs,does the turbine automatically shut off if the LLD detects a leak? <br /> �+ N/A <br /> Yes �' No* For electronic LLDs that are programmed for positive shut down,does the turbine automatically shut off if any portion of the <br /> l+ N/A monitoring system is disabled or disconnected? <br /> Yes r No* For electronic LLDs that are programmed for positive shut down,does the turbine automatically shut off if any portion of the <br /> G N/A monitoring system malfunctions or fails a test? <br /> Yes r No* For electronic LLDs,have all accessible wiring connections been visually inspected? <br /> G N/A <br /> • Yesf No* Were all items on the equipment manufacturer's maintenance checklist completed? <br /> *In the Section H,below,describe how and when these deficiencies were or will be corrected. <br /> H. Comments: <br /> Page 3 of 3 12/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.