My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REMOVAL_PLAN 1991
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
1206
>
2300 - Underground Storage Tank Program
>
PR0231175
>
REMOVAL_PLAN 1991
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/10/2024 1:21:15 PM
Creation date
11/8/2018 9:43:06 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
PLAN 1991
RECORD_ID
PR0231175
PE
2361
FACILITY_ID
FA0001247
FACILITY_NAME
DP & DK Investments, Inc.
STREET_NUMBER
1206
Direction
E
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95210
CURRENT_STATUS
01
SITE_LOCATION
1206 E MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MARCH\1206\PR0231175\REMOVAL PLAN 1991.PDF
QuestysFileName
REMOVAL PLAN 1991
QuestysRecordDate
11/16/2011 8:00:00 AM
QuestysRecordID
178257
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
215
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAO COUNTY PUBLIC HEALTH SERVICES/ENVIRONMENTAL HEALTH DIVISION p <br /> I' UGST WORKSHEET FOR SITE CLOSURE EVALUATION ATE <br /> AME OF FACILITY CJ. �/D�i WEEPS CODE <br /> �// <br /> DRESS �Oti D (D C � / _ _ - ANK W,# <br /> ANK SIZE OQO UEL TYPE � �— <br /> 11. GENERAL SITE HISTORY <br /> ♦� <br /> Is permit current? es 0 ermit q acility Status Code oc.Soi L/GW Cont es o <br /> umber of Tanks at facility ge of Tanks(if available) ype of Tank Leel FbrgL ngl Dual <br /> 111. TANK HISTORY <br /> as Tank tested? es o ailed precision test ? es o If yes, give date(s) (l� j /0 <br /> as a repair made to the tank system? es No f yes, what was repaired? '.1 i7,� �gb < ,n.X LzgcLC,G.'.rc�l'✓�C�! _z <br /> as repair done under inspection? as o ere soil samples analyzed? e o TXE PH-G PH-D b/EDB <br /> Type of failure/discharge atastrophic Iong-term leakage verfiLL nknown they: <br /> IV. REMOVAL HISTORY (ATTACH INSPECTION REPORT FOR SITE DETAILS/COLLECT DATA FOR LEACHING POTENTIAL ANALYSIS) <br /> Suit Samples Received es o epth to Ground Water of/Year Q(2 verage Annual Precipitation = 4 0-25 <br /> -Site Wells) es o umber 8 Type Irr an ub <br /> S Score S core <br /> istance to WetL(s) from Tank ft; ft; ft C 0 pts C pts C pts <br /> 0 t o if 0 f <br /> R conditi onV. R ondition <br /> Site Feature - Leaching Potential Analysis E is met E is met E is met <br /> inimum Depth to groundwater from the Soil Sanple (feet) >100 1-100 25-50L <br /> Fractures in subsurface (applies to foothills or mountain areas) None Unknown resent <br /> %verage Annual Precipitation (inches) xxxxxx <10 9 10-25 xmxmx 26-401 <br /> Ian-Made conduits which increase vertical migration <br /> f leachate e., septic systems, water wells, ponds) None Unknown resent <br /> nique site features: Recharge area, coarse soil, nearby wells. At least ore than <br /> xxxx None one one <br /> COLUMN TOTALS>>>TOTAL POINTS ♦ t <br /> amUpleRe. sult: (B T X OR E) RANGE OF TOTAL POINTS 9 pts or more 41 48 pts 40 pts or Less <br /> 00 <br /> �Ihb7 o f x M(' c o J�Gw 8 T X E B T X E <br /> MAXIMUM ALLOWABLE B-T-X-E LEVELS (PPM) 1 50 50 50 .3 .3 1. 1. NA1 <br /> ample ResuLt: ASOLINE 1000 100 10 <br /> AXIMUM ALLOWABLE TPN LEVELS (PPM) <br /> TPH IESEL 10,000 1000 100 <br /> OOTNOTE S: ---if documented soil and/or ground water contamination Is present, do not canplete the leaching potential <br /> analysis. (i.e., site is currently on UGT Contmnination List for soil or ground water.) <br /> L If depth is > 5 ft, and < 25 ft., score 0 points. If depth <=5 ft., do not use table. <br /> L If precipitation is > 40 inches, score 0 points. <br /> L Levels for BTXBE are not appLicabLe at a TPH concentration of 10 ppm (gasoline) or 100 ppm (diesel). <br /> V1. STAFF RECOMMENDATION/CONCLUSION <br /> It2CC/5p— r�" � Got ,jv FYbu/ <br /> 1. Are BTX 8 E or TPH Concentrations > Allowable Levels Yes o l- aSLZ� -7i q,L� <br /> 2. Recommend Site Closure Yes I o I �If Yes, Refer to Site Mitigation for Evaluation <br /> V11. REVIEW EVALUATION - TO BE COMPLETED BY A SUPERVISOR/SENIOR <br /> CONCUR WITH STAFF RECOMMENDATION FOR CLOSURE ES 0 EFERRED TO SITE MITIGATION FOR EVALUATION ES 0 <br /> ATE REFERRED / / ATE CLOSURE LETTER MAILED <br /> AME OF <br /> `VALUATOR <br /> EH 23 80 (UGTWKSHT)\5/90 <br />
The URL can be used to link to this page
Your browser does not support the video tag.