COMPLIANCE INFO 2002 - 2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARIPOSA
>
2467
>
2300 - Underground Storage Tank Program
>
PR0231818
>
COMPLIANCE INFO 2002 - 2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:06 PM
Creation date
11/8/2018 9:44:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002 - 2013
RECORD_ID
PR0231818
PE
2361
FACILITY_ID
FA0022456
FACILITY_NAME
Foodliner, Inc.
STREET_NUMBER
2467
Direction
E
STREET_NAME
MARIPOSA
STREET_TYPE
Rd
City
Stockton
Zip
95205
APN
17130003
CURRENT_STATUS
02
SITE_LOCATION
2467 E Mariposa Rd
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MARIPOSA\2467\PR0231818\COMPLIANCE INFO 2002 - 2013.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
263
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 Page Z- of <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: ank Manufacturer El Industry Standard El Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure Fi Vacuum ❑ Hydrostatic <br /> ❑Other(Sp y�) <br /> Test Equipment Used: sof f a teru�+1911a«dlJ let Wow ' n t(S Equipment Resolution: —t12,-34 AJ j <br /> Tank#i ITaok# Z ,Tank# Tank# <br /> Is Tank Exempt From Testing?' ❑Yes o ❑Yes Oo ❑Yes ❑No ❑Yes ❑No <br /> Tank Capacity: lZ O32Ggl/�S l ( 3Z rq /oy <br /> Tank Material: « a e K2e LvJ <br /> Tank Manufacturer: d 2p1-n�O1 iYY L11 (} <br /> Product Stored: n,- L 1)g eS e(_ ty <br /> Wait time between applying <br /> press acu ter and 1 <br /> startin test: 1 �04✓ 1 e)LA ✓ ' <br /> Test Start Time: 2 '- 3 U 12-' 36 <br /> Initial Reading(Ri): — 10 — t d (4 <br /> Test End Time: 1 3 [J t <br /> Final Reading(RF): — ' - <br /> Test Duration: <br /> Change in Reading(RF-R,): <br /> Pass/Fail Threshold or Criteria: <br /> Test Result: Pass ❑Fail fZ-Pass ❑Fail ❑ Pass ❑ all Pass ❑lAeil <br /> Was sensor removed for testing? Yes ❑No ❑NA es ❑No ❑NA ❑ es ❑No A Yes ❑No ❑PiA <br /> Was sensor properly replaced and <br /> verified functional after testing? �1 es ❑No ❑NAes ❑No ❑NA Yes ❑No ❑ Yes ❑No ❑NA <br /> Comments— (include information on repairs made prior to testing; and recommended ollow up forLailed tests) <br /> Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br /> testing. f California Code of Regulations, Title 23, Section 2637(a)(6)) <br />