My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2002 - 2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARIPOSA
>
2467
>
2300 - Underground Storage Tank Program
>
PR0231818
>
COMPLIANCE INFO 2002 - 2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:06 PM
Creation date
11/8/2018 9:44:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002 - 2013
RECORD_ID
PR0231818
PE
2361
FACILITY_ID
FA0022456
FACILITY_NAME
Foodliner, Inc.
STREET_NUMBER
2467
Direction
E
STREET_NAME
MARIPOSA
STREET_TYPE
Rd
City
Stockton
Zip
95205
APN
17130003
CURRENT_STATUS
02
SITE_LOCATION
2467 E Mariposa Rd
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MARIPOSA\2467\PR0231818\COMPLIANCE INFO 2002 - 2013.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
263
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Testing/Servicing�– _. <br /> Software Version Installed: <br /> Com a the fo owi.ng checklist: <br /> a-ysj=�j❑ No* is the audible alarm operational? <br /> Peesu ❑ No* Is the visual alarm o erational? <br /> s ❑ No* Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> es ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their proper o eration? <br /> ❑ Yes ❑ No* f--alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br /> _ /A operational? <br /> 57Ves ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> ❑ N/A monitoring system detects a leak, fails to operate,or is electrically disconnected? If yes: which sensors initiate <br /> positive shut-down? (Check all that apply) 8-Sump/Trench Sensors; O'151spenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? t�❑ No. <br /> ❑ Yes ❑ No* or tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br /> EiN/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fillpoint(s)and operating ro erl ? If so,at what percent of tank capacity does the alarm trigger? <br /> ❑ Yes* No Was any monitoring equipment replaced? If yes,identify specific sensors,probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement puts in Section E,below. <br /> Yes* ❑ No Was liquid foun Inside any secondary containment systems designed as dry systems? (Check all that apply)El <br /> Product; ater. If es,describe causes in Section E,below. <br /> ❑ Yes ❑ No* Was monitorings stem set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> ❑ Yes ❑ No* Is all monit)ring equipment oerational per manufacturer's specifications? <br /> *In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: 5iyAy-P bd�ey(e r- i F? bo/_J/ G 1+ 9a 5 ays,a S <br /> t.a) ar f e' r 1t"' Pb 3o r- �0 eo r j' O/u y a/ i vt e a S t- ul� s�J✓">�+ '! <br /> T� PtI :Opror <br /> PP yo 5ou�h ta•ytP � o � >!.�r 9a . <br /> y_AP !tm+ ti tzts-. <br /> /t' It 0 <br /> f-A /a/ oa /ter 90 oa/, <br /> Page 2 of 3 03/01 <br />