Laserfiche WebLink
F'RpNT <br />AD <br />. ` JV1S 43.14 E '0g gs <br />. ` r <br />/ r <br />• .� 11M1rOF I" <br />to oooo � Do <br />' � LIMIT OF WORK W1 •50 0`� - <br />qV29 <br />_ <br />POC <br />µ-. <br />} <br />w.. . ,.., <br />w t = <br />� A <br />co <br />.......... <br />- C co E 't i d'. G, 1t <br />cLu <br />M1 :! co <br />' E7 12'PVC SD 1t 00 <br />a a 23 E11 13 :. z <br />t 35 LF @ 6.87% <br />_ O � � 1� BFP <br />`c <br />E6 <br />: W4 <br />I � <br />{:�:;xµfc k-." <br />1 y E5 l <br />REFER TO AMS ASSOCIATES <br />W2 I-i.� <br />PLANS FOR COORDINATION ? �. �� <br />€ AND CONSTRUCTION OF <br />OVERALL SHOPPING CENTER ; F a ,_ ... <br />SHOPS j <br />i 3 <br />S f L ' S <br />SCALE: 1"=20'-O" <br />20 0 20 40 <br />Legend: <br />General Notes: <br />1 _ BOUNDARY AND TOPOGRAPHIC SURVEY INFORMATION SHOWN IS BY OTHERS_ EDA <br />ASSUMES NO RESPONSIBILITY FOR PRIOR SURVEYS, EASEMENTS, DOCUMENTS, <br />ETC., RELATING TO THIS PROPERTY, OR ENCROACHMENTS INCLUDING, BUT NOT <br />LIMITED TO, WALLS, FENCES, BUILDINGS, TREES OR UTILITIES. <br />2. THE CONTRACTOR SHALL VERIFY EXISTING GRADES AS SHOWN HEREON PRIOR TO <br />COMMENCEMENT OF CONSTRUCTION. IF SIGNIFICANT DISCREPANCIES EXIST <br />BETWEEN "AS -BUILT" INFORMATION AS SHOWN HEREON AND FIELD CONDITIONS <br />THEN THE CONTRACTOR SHALL STOP ALL SURFACE WORK AND CONTACT THE <br />DESIGN ENGINEER FOR REVISIONS. <br />3. THESE PLANS REFERENCE THE CIVIL PLANS FOR EVERGREEN-MORADA RANCH <br />RETAIL CENTER, BY: <br />AMS ASSOCIATES, INC. <br />1350 TREAT BOULEVARD, SUITE 250 <br />WALNUT CREEK, CA 94596 <br />TELEPHONE: (925) 943-2777 <br />FAX: (925) 943-2778 <br />DIAL TOLL FREE <br />1-800-2272600 <br />AT LEAST TWO DAYS <br />BEFORE YOU DIG <br />UNDERGROUND SERVICE ALERT OF CALIFORNIA <br />DRAINAGE KEY: <br />20 INSTALL THREE (3) CARTRIDGE "STORMWATER MANAGEMENT" ASSEMBLY PER DETAIL 1, <br />SHEET C4-2. <br />21 CONSTRUCT "CHRISTY" U21 CATCH BASIN WI TRAFFIC RATED GRATE (OR APPROVED EQUAL) <br />PER DETAIL 2, SHEET C4-2 <br />22 CONSTRUCT "CHRISTY" U21 CATCH BASIN W/ BOLT DOWN LID (OR APPROVED EQUAL) PER <br />DETAIL 2, SHEET C4-2 <br />23 CONSTRUCT PRIVATE 12" PVC STORM DRAIN PER CITY OF STOCKTON STANDARD DRAWINGS <br />AND SPECIFICATIONS <br />24 CONSTRUCT 8" PVC STORM DRAIN PER CITY OF STOCKTON STANDARD DRAWINGS AND <br />SPECIFICATIONS <br />25 CONSTRUCT 8" PVC SDR35 STORM DRAIN PER CITY OF STOCKTON STANDARD DRAWINGS <br />AND SPECIFICATIONS <br />26 CONSTRUCT 4" PVC STORM DRAIN FROM TRENCH DRAIN <br />27 CONSTRUCT 3" PVC SDR35 STORM DRAIN FROM KIOSK ROOF DRAINIDOWNSPOUT TO 8" PVC <br />SDR35 STORM DRAW <br />28 CONSTRUCT 3" PVC SDR35 STORM DRAIN FROM CANOPY DOWNSPOUT TO 8" PVC SDR35 <br />STORM DRAIN <br />29 CONSTRUCT STORM DRAIN CLEAN OUT PER DETAIL 5, SHEET C4-1 <br />30 INSTALL 6" "ALHAMBRA FOUNDRY COMPANY" TRENCH DRAIN WITH GRATE, TYPE 'A-2446' <br />31 INSTALL 10" "NDS" ROUND CATCH BASIN #10605 ON 8" PVC RISER <br />UTILITY KEY: <br />SEWER <br />S1 CONSTRUCT 6" PVC SEWER SERVICE - CONNECT TO SANITARY SEWER MANHOLE (AS SHOWN) <br />52 CONSTRUCT 4"C-0. TO GRADE PER CITY OF STOCKTON STANDARD DRAWING No. 64 <br />(NATER <br />W1 CONSTRUCT 1-112" PVC WATER SERVICE TO KIOSKICAR WASH AND CONNECTTO WATER <br />LINE AS SHOWN <br />W2 CONSTRUCT 314" PVC WATER LINE TO AIRIWATER SERVICE UNIT PER CITY OF STOCKTON <br />STANDARD DRAWINGS AND SPECIFICATIONS <br />W3 CONSTRUCT 314" PVC WATER LINE TO SINK AT CANOPY PER CITY OF STOCKTON <br />STANDARD DRAWINGS AND SPECIFICATIONS <br />W4 CONSTRUCT WATER LINE UTILITY BOX PER DETAIL 2, SHEET C4-1 <br />ELECTRICAL <br />Ei ELECTRICAL TRANSFORMER PAD PER PG&E REQUIREMENTS <br />E2 CONSTRUCT (2) 5" CONDUIT FOR 600 AMP, 120-208V, 3-PHASE 4 -WIRE ELECTRICAL SERVICE <br />TO KIOSK PER PG&E PLANS <br />E3 CONSTRUCT (1) 314" PVC CONDUIT FOR ELECTRIC SERVICE TO AIRIWATER UNIT <br />OE4 <br />CONSTRUCT R T 2 1" PVC CONDUIT FOR SERVICE TO PRICING SIGN <br />E5 PROVIDE (1) 314" PVC CONDUIT FOR THE VENT RISER ASSEMBLY, SEE TANK INSTALLATION <br />DRAWINGS FOR ELECTRICAL WIRING REQUIREMENTS <br />E6 <br />PROVIDE 1 314" CONDUIT WITH PULL ROPES FOR FUTURE USE AT VENT RISER <br />E7 PROVIDE (1) 3/4" PVC CONDUIT FOR THE EMERGENCY PUMP SHUT OFF SWITCH STATION, SEE <br />TANK INSTALLATION DRAWINGS FOR ELECTRICAL WIRING REQUIREMENTS <br />E8 CONSTRUCT (1) 3/4" PVC CONDUIT FOR ELECTRIC SERVICE TO LIGHT STANDARD <br />E9 CONSTRUCT ELECTRICAL VAULT PER ELECTRICAL DRAWINGS <br />E10 CONSTRUCT (2) 1" PVC CONDUIT FOR ELECTRIC SERVICE TO CAR WASH ENTRANCE SYSTEM <br />011 CONSTRUCT (1) 3/4" PVC CONDUIT FOR ELECTRIC SERVICE TO VACUUM STATION <br />Utility Plan Notes: <br />1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ITEMS SHOWN ON ALL SHEETS OF THE <br />PLANS. <br />2. ALL WORK SHOWN ON THESE PLANS SHALL BE VERIFIED FOR DIMENSION, GRADE, EXTENT AND <br />COMPATIBILITY TO THE EXISTING BUILDING SITE. ANY DISCREPANCIES AND UNEXPECTED <br />CONDITIONS THAT EFFECT OR CHANGE THE WORK DESCRIBED HEREIN SHALL BE BROUGHT TO <br />THE OWNER'S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF <br />DISCREPANCY UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES <br />TO PROCEED, HE SHALL DO SO AT HIS OWN EXPENSE. <br />3. ALL IMPROVEMENTS SHALL BE CONSTRUCTED AND INSTALLED PER THE LATEST VERSION OF THE <br />STANDARDS, SPECIFICATIONS, AND ORDINANCES OF THE CITY OF STOCKTON AND THE UNIFORM <br />BUILDING CODE, LATEST EDITION. <br />4. THE DECISION OF THE CITY BUILDING OFFICIAL SHALL BE FINAL REGARDING SPECIFIC STANDARDS <br />THAT SHALL APPLY AND ALL WORK SHALL BE SUBJECT TO THE APPROVAL OF THE CITY BUILDING <br />OFFICIAL. <br />5. NO CONSTRUCTION SHALL BE STARTED WITHOUT PLANS APPROVED BY THE CITY BUILDING <br />DEPARTMENT. THE CITY OF STOCKTON SHALL BE NOTIFIED AT LEAST 24 HOURS PRIOR TO <br />STARTING CONSTRUCTION. ANY CONSTRUCTION DONE WITHOUT APPROVED PLANS OR PRIOR <br />NOTIFICATION TO THE CITY BUILDING DEPARTMENT WILL BE REJECTED AND WILL BE DONE AT THE <br />CONTRACTORS AND/OR OWNERS OWN RISK. <br />6. ALL UTILITIES SHOWN ARE CORRECT AND ACCURATE TO THE EXTENT OF AVAILABLE RECORDS <br />AND KNOWLEDGE. THE CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR <br />THE LOCATION OF ALL UNDER GROUND UTILITIES AND OTHER FACILITIES AND FOR PROTECTING <br />SAME DURING THE COURSE OF CONSTRUCTION. <br />7_ IF EXISTING UTILITIES ARE DAMAGED AS A RESULT OF THE CONTRACTOR'S WORK, CONTRACTOR <br />SHALL REPLACE OR REPAIR SAID DAMAGE AT NO COST TO THE OWNER. <br />8. THE CONTRACTOR SHALL FOLLOW ALL APPLICABLE INDUSTRIAL SAFETY REGULATIONS. THE CITY <br />OF STOCKTON, ITS' OFFICIALS, THE ARCHITECT, THE ENGINEER, AND THE OWNER SHALL NOT BE <br />HELD RESPONSIBLE FOR ENFORCING SAFETY REGULATIONS, <br />9. THE CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICES ALERT, AT 1.800.227.2600, <br />FORTY-EIGHT (48) HOURS PRIOR TO THE START OF CONSTRUCTION (GOVERNMENT CODE SECTION <br />421614217). <br />10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING THE APPROPRIATE AGENCY FOR THE <br />LOCATION OF ALL UNDERGROUND FACILITIES. <br />11. ADDRESS NUMBERS SHALL BE POSTED ON THE BUILDING SO AS TO BE PLAINLY VISIBLE AND <br />CLEARLY LEGIBLE FROM THE FRONTAGE STREET, NUMBER SHALL BE A MINIMUM OF 6 INCHES IN <br />HEIGHT AND SHALL BE DISPLAYED ON A CONTRASTING BACKGROUND. <br />12. GAS METERS, ELECTRIC UTILITIES ANDIOR ANY PART OF A FIRE PROTECTION WATER SYSTEM <br />SUBJECT TO VEHICULAR DAMAGE SHALL BE PROVIDED WITH IMPACT PROTECTION. FIRE <br />EXTINGUISHERS SHALL BE INSTALLED AND MAINTAINED IN SUCH LOCATIONS AS MAY BE <br />DETERMINED BY THE FIRE MARSHALL. PORTABLE FIRE EXTINGUISHER SHALL HAVE A MINIMUM <br />RATING OF 2A-10BC. SEE SHEET CA1-1 FOR ACTUAL LOCATION OF FIRE EXTINGUISHER(S). <br />13. PRIOR TO WORKING IN THE PUBLIC RIGHT-OF-WAY, THE CONTRACTOR SHALL SECURE AN <br />ENCROACHMENT PERMIT FROM THE CITY OF STOCKTON PUBLIC WORKS DEPARTMENT, <br />14. ALL PARKING LOT CONDUITS SHALL HAVE A MINIMUM COVER OF 24 INCHES PER NEC. 300-5 (9) Ex. <br />3_ ALL ELECTRICAL UTILITY INSTALLATIONS SHALL COMPLY WITH ARTICLE 514-5 OF THE NEC. <br />LATEST EDITION_ ALL UTILITY TRENCH SECTIONS AND BACKFILL SHALL CONFORM TO THE CITY OF <br />STOCKTON STANDARDS & SPECIFICATIONS AND/OR RECOMMENDATIONS CONTAINED IN THE SOILS <br />REPORT, WHICH EVER IS MORE STRICT. <br />15. SAWCUT OF EXISTING PAVEMENT SHALL BE ALONG A NEAT VERTICAL LINE PARALLEL TO THE <br />UTILITY WHERE POSSIBLE AS DIRECTED BY THE ENGINEER OF WORK. REPLACEMENT PAVEMENT <br />SECTION SHALL BE IN KIND ANDIOR PER CITY OF STOCKTON STANDARDS AND SPECIFICATIONS. <br />N} 1:; l. I. <br />YY� <br />1- <br />500 WEST CAPITOL AVENUE <br />WEST SACRAMENTO, CA <br />95605 <br />P.O. BOX 15618 SACRAMENTO, CA <br />95852 <br />REVISIONS <br />A <br />A <br />A <br />design <br />professionals <br />civil engineers . land surveyors s land planners <br />1998 sante barbara st . san lugs ohispo, ca 43401 <br />ph: 8051549-8658 • email: eda@edainc.com <br />OVESS I <br />Lic. No_ 26,431 <br />Expires 3131106 <br />Of=L <br />CA <br />SHEET TITLE <br />UTILITY PLAN <br />PROJECT NAME <br />RALEY'S #356 <br />FUEL CENTER <br />FRONTAGE ROAD & <br />MORADA LANE <br />STOCKTON, CALIFORNIA <br />PROJECT NO. <br />2.3208.000 <br />DRAWN BY <br />SCALE <br />AS SHOWN <br />E] DATE <br />23 JUNE 2005 <br />PAGE NO. <br />U2-1 <br />SHEET OF <br />d <br />uj SAWCUT <br />LINE <br />- -- . — . NEW SEWER LINE <br />z <br />O <br />U) <br />0 <br />PROJECT BOUNDARY & ROW <br />EXISTING SEWER LINE <br />X <br />w <br />w <br />:7 n_ <br />LOT LINE & ROW <br />NEW STORM DRAIN .. .. <br />FIRE HYDRANT <br />EASEMENT <br />EXISTING STORM DRAIN r � .......,_.,�. __...__T ae._ ___• _ ._r-.,._ ,...,,r -,. <br />WATER VALVE <br />e <br />WATER METER <br />a <br />CENTERLINE - <br />- NEW GAS LINE <br />WATER BLOWOFF <br />NEW FENCE CHAIN - <br />G U - EXISTING GAS LINE - ._._ <br />CLEANOUT <br />%% <br />w <br />EXISTING FENCE CHAIN <br />NEW WIRE LINE <br />MANHOLE <br />O- <br />NEW FENCE WIRE <br />X - X - X EXISTING WIRE LINE <br />ROAD MONUMENT <br />• <br />EXISTING FENCE WIRE <br />-.-_.._ _.. _ _ __..- _ _. _ PATH OF TRAVEL - - - - - - ---- ---- ------ - - ----- - - ---- <br />JUNCTION POLE <br />UTILITY GUY <br />NEW FENCE WOOD <br />❑ ❑ <br />STREET LIGHT <br />E <br />EXISTING FENCE WOOD - <br />517E LIGHT <br />`.... <br />❑ o <br />...' <br />EXISTING WALL <br />STREET SIGN <br />i <br />NEW WALL <br />TRANSFORMER <br />® <br />NEW WATERLINE <br />- <br />EXISTING WATERLINE ..:.__N......,.......,,...,..._.. <br />...,:.._....:,.:.._w.�....,-.,._ _,.a,... -._s_..,...__._.,.. -__ <br />WIRE P U LL BOXES <br />DIAL TOLL FREE <br />1-800-2272600 <br />AT LEAST TWO DAYS <br />BEFORE YOU DIG <br />UNDERGROUND SERVICE ALERT OF CALIFORNIA <br />DRAINAGE KEY: <br />20 INSTALL THREE (3) CARTRIDGE "STORMWATER MANAGEMENT" ASSEMBLY PER DETAIL 1, <br />SHEET C4-2. <br />21 CONSTRUCT "CHRISTY" U21 CATCH BASIN WI TRAFFIC RATED GRATE (OR APPROVED EQUAL) <br />PER DETAIL 2, SHEET C4-2 <br />22 CONSTRUCT "CHRISTY" U21 CATCH BASIN W/ BOLT DOWN LID (OR APPROVED EQUAL) PER <br />DETAIL 2, SHEET C4-2 <br />23 CONSTRUCT PRIVATE 12" PVC STORM DRAIN PER CITY OF STOCKTON STANDARD DRAWINGS <br />AND SPECIFICATIONS <br />24 CONSTRUCT 8" PVC STORM DRAIN PER CITY OF STOCKTON STANDARD DRAWINGS AND <br />SPECIFICATIONS <br />25 CONSTRUCT 8" PVC SDR35 STORM DRAIN PER CITY OF STOCKTON STANDARD DRAWINGS <br />AND SPECIFICATIONS <br />26 CONSTRUCT 4" PVC STORM DRAIN FROM TRENCH DRAIN <br />27 CONSTRUCT 3" PVC SDR35 STORM DRAIN FROM KIOSK ROOF DRAINIDOWNSPOUT TO 8" PVC <br />SDR35 STORM DRAW <br />28 CONSTRUCT 3" PVC SDR35 STORM DRAIN FROM CANOPY DOWNSPOUT TO 8" PVC SDR35 <br />STORM DRAIN <br />29 CONSTRUCT STORM DRAIN CLEAN OUT PER DETAIL 5, SHEET C4-1 <br />30 INSTALL 6" "ALHAMBRA FOUNDRY COMPANY" TRENCH DRAIN WITH GRATE, TYPE 'A-2446' <br />31 INSTALL 10" "NDS" ROUND CATCH BASIN #10605 ON 8" PVC RISER <br />UTILITY KEY: <br />SEWER <br />S1 CONSTRUCT 6" PVC SEWER SERVICE - CONNECT TO SANITARY SEWER MANHOLE (AS SHOWN) <br />52 CONSTRUCT 4"C-0. TO GRADE PER CITY OF STOCKTON STANDARD DRAWING No. 64 <br />(NATER <br />W1 CONSTRUCT 1-112" PVC WATER SERVICE TO KIOSKICAR WASH AND CONNECTTO WATER <br />LINE AS SHOWN <br />W2 CONSTRUCT 314" PVC WATER LINE TO AIRIWATER SERVICE UNIT PER CITY OF STOCKTON <br />STANDARD DRAWINGS AND SPECIFICATIONS <br />W3 CONSTRUCT 314" PVC WATER LINE TO SINK AT CANOPY PER CITY OF STOCKTON <br />STANDARD DRAWINGS AND SPECIFICATIONS <br />W4 CONSTRUCT WATER LINE UTILITY BOX PER DETAIL 2, SHEET C4-1 <br />ELECTRICAL <br />Ei ELECTRICAL TRANSFORMER PAD PER PG&E REQUIREMENTS <br />E2 CONSTRUCT (2) 5" CONDUIT FOR 600 AMP, 120-208V, 3-PHASE 4 -WIRE ELECTRICAL SERVICE <br />TO KIOSK PER PG&E PLANS <br />E3 CONSTRUCT (1) 314" PVC CONDUIT FOR ELECTRIC SERVICE TO AIRIWATER UNIT <br />OE4 <br />CONSTRUCT R T 2 1" PVC CONDUIT FOR SERVICE TO PRICING SIGN <br />E5 PROVIDE (1) 314" PVC CONDUIT FOR THE VENT RISER ASSEMBLY, SEE TANK INSTALLATION <br />DRAWINGS FOR ELECTRICAL WIRING REQUIREMENTS <br />E6 <br />PROVIDE 1 314" CONDUIT WITH PULL ROPES FOR FUTURE USE AT VENT RISER <br />E7 PROVIDE (1) 3/4" PVC CONDUIT FOR THE EMERGENCY PUMP SHUT OFF SWITCH STATION, SEE <br />TANK INSTALLATION DRAWINGS FOR ELECTRICAL WIRING REQUIREMENTS <br />E8 CONSTRUCT (1) 3/4" PVC CONDUIT FOR ELECTRIC SERVICE TO LIGHT STANDARD <br />E9 CONSTRUCT ELECTRICAL VAULT PER ELECTRICAL DRAWINGS <br />E10 CONSTRUCT (2) 1" PVC CONDUIT FOR ELECTRIC SERVICE TO CAR WASH ENTRANCE SYSTEM <br />011 CONSTRUCT (1) 3/4" PVC CONDUIT FOR ELECTRIC SERVICE TO VACUUM STATION <br />Utility Plan Notes: <br />1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ITEMS SHOWN ON ALL SHEETS OF THE <br />PLANS. <br />2. ALL WORK SHOWN ON THESE PLANS SHALL BE VERIFIED FOR DIMENSION, GRADE, EXTENT AND <br />COMPATIBILITY TO THE EXISTING BUILDING SITE. ANY DISCREPANCIES AND UNEXPECTED <br />CONDITIONS THAT EFFECT OR CHANGE THE WORK DESCRIBED HEREIN SHALL BE BROUGHT TO <br />THE OWNER'S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF <br />DISCREPANCY UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES <br />TO PROCEED, HE SHALL DO SO AT HIS OWN EXPENSE. <br />3. ALL IMPROVEMENTS SHALL BE CONSTRUCTED AND INSTALLED PER THE LATEST VERSION OF THE <br />STANDARDS, SPECIFICATIONS, AND ORDINANCES OF THE CITY OF STOCKTON AND THE UNIFORM <br />BUILDING CODE, LATEST EDITION. <br />4. THE DECISION OF THE CITY BUILDING OFFICIAL SHALL BE FINAL REGARDING SPECIFIC STANDARDS <br />THAT SHALL APPLY AND ALL WORK SHALL BE SUBJECT TO THE APPROVAL OF THE CITY BUILDING <br />OFFICIAL. <br />5. NO CONSTRUCTION SHALL BE STARTED WITHOUT PLANS APPROVED BY THE CITY BUILDING <br />DEPARTMENT. THE CITY OF STOCKTON SHALL BE NOTIFIED AT LEAST 24 HOURS PRIOR TO <br />STARTING CONSTRUCTION. ANY CONSTRUCTION DONE WITHOUT APPROVED PLANS OR PRIOR <br />NOTIFICATION TO THE CITY BUILDING DEPARTMENT WILL BE REJECTED AND WILL BE DONE AT THE <br />CONTRACTORS AND/OR OWNERS OWN RISK. <br />6. ALL UTILITIES SHOWN ARE CORRECT AND ACCURATE TO THE EXTENT OF AVAILABLE RECORDS <br />AND KNOWLEDGE. THE CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR <br />THE LOCATION OF ALL UNDER GROUND UTILITIES AND OTHER FACILITIES AND FOR PROTECTING <br />SAME DURING THE COURSE OF CONSTRUCTION. <br />7_ IF EXISTING UTILITIES ARE DAMAGED AS A RESULT OF THE CONTRACTOR'S WORK, CONTRACTOR <br />SHALL REPLACE OR REPAIR SAID DAMAGE AT NO COST TO THE OWNER. <br />8. THE CONTRACTOR SHALL FOLLOW ALL APPLICABLE INDUSTRIAL SAFETY REGULATIONS. THE CITY <br />OF STOCKTON, ITS' OFFICIALS, THE ARCHITECT, THE ENGINEER, AND THE OWNER SHALL NOT BE <br />HELD RESPONSIBLE FOR ENFORCING SAFETY REGULATIONS, <br />9. THE CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICES ALERT, AT 1.800.227.2600, <br />FORTY-EIGHT (48) HOURS PRIOR TO THE START OF CONSTRUCTION (GOVERNMENT CODE SECTION <br />421614217). <br />10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING THE APPROPRIATE AGENCY FOR THE <br />LOCATION OF ALL UNDERGROUND FACILITIES. <br />11. ADDRESS NUMBERS SHALL BE POSTED ON THE BUILDING SO AS TO BE PLAINLY VISIBLE AND <br />CLEARLY LEGIBLE FROM THE FRONTAGE STREET, NUMBER SHALL BE A MINIMUM OF 6 INCHES IN <br />HEIGHT AND SHALL BE DISPLAYED ON A CONTRASTING BACKGROUND. <br />12. GAS METERS, ELECTRIC UTILITIES ANDIOR ANY PART OF A FIRE PROTECTION WATER SYSTEM <br />SUBJECT TO VEHICULAR DAMAGE SHALL BE PROVIDED WITH IMPACT PROTECTION. FIRE <br />EXTINGUISHERS SHALL BE INSTALLED AND MAINTAINED IN SUCH LOCATIONS AS MAY BE <br />DETERMINED BY THE FIRE MARSHALL. PORTABLE FIRE EXTINGUISHER SHALL HAVE A MINIMUM <br />RATING OF 2A-10BC. SEE SHEET CA1-1 FOR ACTUAL LOCATION OF FIRE EXTINGUISHER(S). <br />13. PRIOR TO WORKING IN THE PUBLIC RIGHT-OF-WAY, THE CONTRACTOR SHALL SECURE AN <br />ENCROACHMENT PERMIT FROM THE CITY OF STOCKTON PUBLIC WORKS DEPARTMENT, <br />14. ALL PARKING LOT CONDUITS SHALL HAVE A MINIMUM COVER OF 24 INCHES PER NEC. 300-5 (9) Ex. <br />3_ ALL ELECTRICAL UTILITY INSTALLATIONS SHALL COMPLY WITH ARTICLE 514-5 OF THE NEC. <br />LATEST EDITION_ ALL UTILITY TRENCH SECTIONS AND BACKFILL SHALL CONFORM TO THE CITY OF <br />STOCKTON STANDARDS & SPECIFICATIONS AND/OR RECOMMENDATIONS CONTAINED IN THE SOILS <br />REPORT, WHICH EVER IS MORE STRICT. <br />15. SAWCUT OF EXISTING PAVEMENT SHALL BE ALONG A NEAT VERTICAL LINE PARALLEL TO THE <br />UTILITY WHERE POSSIBLE AS DIRECTED BY THE ENGINEER OF WORK. REPLACEMENT PAVEMENT <br />SECTION SHALL BE IN KIND ANDIOR PER CITY OF STOCKTON STANDARDS AND SPECIFICATIONS. <br />N} 1:; l. I. <br />YY� <br />1- <br />500 WEST CAPITOL AVENUE <br />WEST SACRAMENTO, CA <br />95605 <br />P.O. BOX 15618 SACRAMENTO, CA <br />95852 <br />REVISIONS <br />A <br />A <br />A <br />design <br />professionals <br />civil engineers . land surveyors s land planners <br />1998 sante barbara st . san lugs ohispo, ca 43401 <br />ph: 8051549-8658 • email: eda@edainc.com <br />OVESS I <br />Lic. No_ 26,431 <br />Expires 3131106 <br />Of=L <br />CA <br />SHEET TITLE <br />UTILITY PLAN <br />PROJECT NAME <br />RALEY'S #356 <br />FUEL CENTER <br />FRONTAGE ROAD & <br />MORADA LANE <br />STOCKTON, CALIFORNIA <br />PROJECT NO. <br />2.3208.000 <br />DRAWN BY <br />SCALE <br />AS SHOWN <br />E] DATE <br />23 JUNE 2005 <br />PAGE NO. <br />U2-1 <br />SHEET OF <br />