My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1986-2003
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
I
>
INTERNATIONAL
>
1115
>
2300 - Underground Storage Tank Program
>
PR0231707
>
COMPLIANCE INFO_1986-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2024 4:37:00 PM
Creation date
11/8/2018 9:46:25 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-2003
RECORD_ID
PR0231707
PE
2361
FACILITY_ID
FA0003948
FACILITY_NAME
PG&E TRACY MAINTENANCE STATION
STREET_NUMBER
1115
Direction
N
STREET_NAME
INTERNATIONAL
STREET_TYPE
PKWY
City
TRACY
Zip
95377
APN
209-080-06
CURRENT_STATUS
02
SITE_LOCATION
1115 N INTERNATIONAL PKWY
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\wng
Supplemental fields
FilePath
\MIGRATIONS3\M\MOUNTAIN HOUSE\24081\PR0231707\COMPLIANCE INFO 1986-2003.PDF
QuestysFileName
COMPLIANCE INFO 1986-2003
QuestysRecordDate
8/11/2017 9:19:31 PM
QuestysRecordID
3574393
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
182
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 • • Page 2 of 7 <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: ❑Tank Manufacturer lZlndustry Standard ❑Professional Engineer <br /> L1 Other(Spec) <br /> Test Method Used: ❑Pressure X Vacuum ❑Hydrostatic <br /> 11 Other(Sped) i <br /> Test Equipment Used: Equipment Resolution: <br /> 707dern <br /> Tank# Z Tank# Tank# <br /> Is Tank Exempt From Testing?' No ❑Yes X No ❑Yes ❑No ❑ Yes ❑No <br /> Tank Capacity: .3 �/G 4 j <br /> Tank Materialtee CC <br /> Tank Manufacturer: �cl,'n lhod p n h,-f <br /> Product Stored: g7 0,' . ,e <br /> Wait time between applying <br /> pressure/vacuum/water and <br /> starting test: U r•,,'h <br /> Test Start Time: U fi U <br /> Initial Reading(111): f <br /> Test End Time: <br /> Final Reading(RF): _ <br /> Test Duration: �D <br /> Change in Reading(RF-Rj): <br /> Pass/Fail Threshold or Criteria: <br /> Test Result: Pass ❑Fail ❑ Pass ❑Fail` ❑ Pass ❑Fail ❑ Pass 0 Fail <br /> Was sensor removed for testing? Yes ❑No DNA L1Yes �No 11NA ❑Yes ❑No [INA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and <br /> verified functional after testing? [ Yes ❑No ❑NA ❑Yes [dNo ❑NA ❑Yes ❑No ❑NA ❑Yes ElNo ❑NA <br /> Comments— (include information on repairs made prior to testing and recommended ollow-up orfailed tests) <br /> 1,1nci hl-e_ J-d 40 j 11 fin i,4Inr Z 5(t)j-o OLi 5t-4e k 4ft-ht l-;p <br /> of �n k <br /> SPnSUr <br /> 65s GvaN . C - <br /> Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. {California Code of Regulations,Title 23, Section 2637(a)(6)1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.