COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CAMBRIDGE
>
16470
>
2300 - Underground Storage Tank Program
>
PR0231532
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/5/2022 11:21:35 AM
Creation date
11/8/2018 9:47:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0231532
PE
2351
FACILITY_ID
FA0000185
FACILITY_NAME
CITY FOOD & LIQUOR
STREET_NUMBER
16470
STREET_NAME
CAMBRIDGE
STREET_TYPE
ST
City
LATHROP
Zip
95330
APN
19643032
CURRENT_STATUS
03
SITE_LOCATION
16470 CAMBRIDGE ST
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\C\CAMBRIDGE\16470\PR0231532\COMPLIANCE INFO.PDF
QuestysFileName
COMPLIANCE INFO
QuestysRecordDate
10/22/2012 8:00:00 AM
QuestysRecordID
131132
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
993
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 <br /> Page 3 <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: 2 <br /> Sump Manufacturer Industry Standard ❑X Professional Engineer <br /> Other (Specify) <br /> Test Method Used: F] Pressure Vacuum Hydrostatic <br /> Other (Spec) <br /> Test Equipment Used: Vp1t Equipment Resolution: inches <br /> Sump# 1 UNL Sump# 2 SUP Sump Sump# <br /> Sump Diameter: 48-1 4 8" <br /> Sump Depth: 74' 74" <br /> Sump Material: fiberglass fiberglass <br /> Height from Tank Top to Top of 17" 17" <br /> Highest Piping Pentration: <br /> Height from Tank Top to Lowest 26-1 <br /> 261- <br /> Electrical Pentration: <br /> Condition of sump prior to testing: good good <br /> Portion of Sump Tested: t 19'. 19" <br /> Does turbine shut down when <br /> sump sensor detects liquid(bothx❑yes�No�N X❑yes�No�N E]Yes❑N�N �Yes❑NoF <br /> product and water)?* <br /> Turbine shutdown response time: 2-5sec 2-5sec <br /> Is system programmed for fail-safe es NoN Eyes 1 �NYes �shutdown? <br /> N Yes o <br /> Was fail-safe verified to be 1EYes❑NoEIN X❑ —]No <br /> [:]NA as fail-safe Yes N [flYes R Yes o <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5min 5min <br /> test: <br /> Test Start Time: 10:41 9:33 <br /> Initial Reading(RI): 0 0 <br /> Test End Time: 11:11 10:03 <br /> Final Reading(RF): -.0005" -.0019" <br /> Test Duration: 30min 30min <br /> Change inReading(RF-Rt ): -.0005" - .0019" <br /> Pass/Fail Threshold or Criteria: .002" .002" <br /> Test Result: I E Pass ❑ Fail I X❑Pass ❑ Fail ❑Pass Fail Pass Fail <br /> Was sensor removed for testing? Yes N N R Yes N NA E]Yes N NA Yes No <br /> Was sensor properly replaced and ^ <br /> verified functional after testing? j]Y ^Nc[:]N A R YeC]NcE1N ❑A Y ^N A❑ ❑Yes N <br /> Comments- (include information on repairs made prior to testing, and recommended follow-up forfailed tests) <br /> t If the entire depth of the sump is not tested,specify how much was tested.If the answer to my-of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />