My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CAMBRIDGE
>
16470
>
2300 - Underground Storage Tank Program
>
PR0231532
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/5/2022 11:21:35 AM
Creation date
11/8/2018 9:47:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0231532
PE
2351
FACILITY_ID
FA0000185
FACILITY_NAME
CITY FOOD & LIQUOR
STREET_NUMBER
16470
STREET_NAME
CAMBRIDGE
STREET_TYPE
ST
City
LATHROP
Zip
95330
APN
19643032
CURRENT_STATUS
03
SITE_LOCATION
16470 CAMBRIDGE ST
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\C\CAMBRIDGE\16470\PR0231532\COMPLIANCE INFO.PDF
QuestysFileName
COMPLIANCE INFO
QuestysRecordDate
10/22/2012 8:00:00 AM
QuestysRecordID
131132
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
993
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Circle K Stores Inc.-West Coast Business Unit <br /> 495 East Rincon,Suite 150 <br /> so Corona,CA 92879 <br /> qualified personnel and make appropriate adjustment to make the float and chains detect leak at <br /> the earliest point A permit must be taken out for the work done. <br /> Response: <br /> Our service vendor(Elite IV)obtained the required permit from your Office and adjusted the <br /> floats and chains to detect a leak at the earliest possible point. <br /> Issue#4: <br /> The 87 spill bucket failed the hour hydrostatic test. Immediately repair/replace the spill bucket <br /> with a permit from this Office. <br /> Response: <br /> Our service vendor(Elite IV)obtained the required permit from your office and replaced a spill <br /> bucket for one of the tanks. Unfortunately,the spill bucket was replaced for the wrong tank. We <br /> have requested our service vendor to rectify this immediately by obtaining another permit from <br /> your Office and replace the spill bucket for the appropriate tank. You should see the additional <br /> permit application within the next few days. <br /> Issue#5: <br /> Could not locate facility Designated Systems Operator statement or the D.O.training record for <br /> the UST employees. Immediately prepare a D.O. statement and submit to this Office,also locate <br /> D.O.employee training records and submit a copy to this Office by 6/15/08. An employee must <br /> be trained by the D.O.within 30 days of hire and annually there after. <br /> Response: <br /> I have enclosed a copy of the Owner Statements of Designated Underground Storage Tank(UST) <br /> Operator and Understanding of and Compliance with UST Requirements for your information. A <br /> copy has also been forwarded to the store manager to maintain at the store. I have also enclosed <br /> copies of the D.O.training records. Copies of these training records were left with the store <br /> manager to be maintained at the store. <br /> Issue#6: <br /> A return to compliance must be submitted to this Office by 6/15/08. The annular space for the 91 <br /> tank is under investigation. There was unexplained alarms and liquid fluctuations. LC Services <br /> have been hired by the facility owner to perform repairs. <br /> Response: <br /> As we discussed in our last phone conversation,LC Services requested Xerxes to consider the <br /> impact to the tank of a short term exposure of brine fluid in the annular riser at a measurement in <br /> excess of 12-inches. LC Services also requested Xerxes to modify their previous letter if a short <br /> term exposure was acceptable. 1 have enclosed a copy of the letter from Xerxes dated June 11, <br /> 2008. The letter states"Using the monitor for a reservoir should not damage the tank as long as <br /> the brine level is no higher than 12"above the top of the tank for over 12 continuous hours. The <br /> brine level should never be allowed to be over 36"above the top of the tank,especially when the <br /> tank is empty." Circle K proposes the following plan: relocate the annular riser to the other end <br /> of the tank, refill the annular space with brine to no more the 6"above the top of the tank, install <br /> and adjust the annular sensor,drop a full load of fuel under the supervision of a qualified service <br /> technician who will adjust the brine level if needed,and place the tank system back in service. <br /> Circle K would also put our service provider on a mandatory 8-hour emergency response for this <br />
The URL can be used to link to this page
Your browser does not support the video tag.