COMPLIANCE INFO 1990 - 2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1789
>
2300 - Underground Storage Tank Program
>
PR0506538
>
COMPLIANCE INFO 1990 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:21 AM
Creation date
11/8/2018 9:47:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1990 - 2008
RECORD_ID
PR0506538
PE
2361
FACILITY_ID
FA0007486
FACILITY_NAME
COUNTRY MARKETPLACE
STREET_NUMBER
1789
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16337023
CURRENT_STATUS
01
SITE_LOCATION
1789 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\C\CHARTER\1789\PR0506538\COMPLIANCE INFO 1990 - 2008 .PDF
QuestysFileName
COMPLIANCE INFO 1990 - 2008
QuestysRecordDate
11/16/2016 9:54:06 PM
QuestysRecordID
3259375
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
413
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page _� of <br /> 6. PIPING:SUMP TESTING <br /> Test Method Developed By: ❑Sump Manufacturer Industry Standard ■Professional Engineer <br /> ' ❑Other(Specify) <br /> Te_t Method I ked- r,Preec.TC Vacii. 6 Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: M A4 Ra 'Tjcr Equipment Resolution: .On 1 11 <br /> Sump# / - 97 Sump# Z - Ck Sump# Sump# <br /> Sump Diameter. T 10 491, <br /> Sump Depth: If 8 " S <br /> Sump Material: F//fEyL64}SS rl4cxg LAS <br /> Height from Tank Top to Top of <br /> Highest Piping Penetration: Z t 23 tt <br /> Height from Tank Top to Lowest Z 2 <br /> Electrical Penetration: <br /> Condition of sump prior to testing: G u v 06�o <br /> Portion of Sump Tested' 76 " r <br /> Does turbine shut down when A Yes E No � NA <br /> sump sensor detects either product EYes --,No a NA a Yes ❑No [INA ❑Yes ❑No ENA <br /> or water? <br /> Turbine shutdown response timet 46 SeC_ <br /> Is system programmed for fail-safe III Yes D-1No 71 NA <br /> shutdown? Yes u No ❑NA ❑Yes J No CNA a Yes u No NA <br /> Was fail-safe verified to be ❑Yes 0 No a NA ❑Yes !No ❑NA n Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> operational? <br /> Wait time between applying - <br /> pressure/vacuum/water and starting <br /> test: t0 IrK ftj Q ryk Liu <br /> Test Start Time: / 41 -132 i s—- Z S <br /> Initial Reading(Rt): D :000 h <br /> Test End Time: <br /> Final Reading(RF): -- Q • av a '• ,0,0 r. <br /> Test Duration: Z wr lAi <br /> Change in Reading CKF, uu 0 " '000 " <br /> Pass/Fail Threshold or Criteria:'. t u u1'r J'. u 02-11 <br /> Test Result: N Pass ❑Fail ■ Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail <br /> Was sensor removed for testing? H Yes; G No LINA E Yes ❑No [INA O Yes ❑No [INA ❑Yes ❑No C NA <br /> Was sensor properly replaced and 2-Yes ❑No ❑NA Yes ❑No ❑NA ❑Yes ❑No ❑NA []Yes ❑No LINA <br /> verified functional atter <br /> Comments-(include information on repairs made prior to testing,and recommended jollow-up jorjaded tests) <br /> If the testing method does not test the entire depth of the sump,specify how much of the sump was tested. Methods not testing the <br /> entire sump should only be used if the monitoring system provides fail-safe turbine shutdown. (See SWRCB LG-160) <br /> z With the submersible pump running,place the sensor in product(discriminating sensors should also be placed in water). The time <br /> between placing the sensor in product and the turbine shutting down is the response time. This should be done if the"secondary <br /> containment testing method used does not test the entire volume of the stoop. <br /> This information is not needed if the entire sump is tested. <br />
The URL can be used to link to this page
Your browser does not support the video tag.