My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1789
>
2300 - Underground Storage Tank Program
>
PR0506538
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:24 AM
Creation date
11/8/2018 9:47:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0506538
PE
2361
FACILITY_ID
FA0007486
FACILITY_NAME
COUNTRY MARKETPLACE
STREET_NUMBER
1789
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16337023
CURRENT_STATUS
01
SITE_LOCATION
1789 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\C\CHARTER\1789\PR0506538\COMPLIANCE INFO 2016 - PRESENT.pdf
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
11/18/2016 5:11:43 PM
QuestysRecordID
3261353
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209) 468-3433 Web:www.sigov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> COUNTRY MARKETPLACE 1789 W CHARTER WAY STOCKTON March 08 2016 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,GLASS ll,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 207 CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to document all the alarms from the attached alarm history on the January 2016 <br /> designated operator monthly inspection report and failed to check that they were responded to appropriately. The <br /> missing alarms include: L1 91 annular 1/16/16. The alarm was listed on the report, but no response was noted and no <br /> maintenance records were available on site documenting the corrective actions taken in response to this alarm. <br /> During the monthly inspection, the designated operator shall review the alarm history for the previous month, check <br /> that each alarm was documented and responded to appropriately, and attach a copy of the alarm history with <br /> documentation taken in response to any alarms to the monthly report. Ensure that designated operators performing <br /> monthly inspections at this facility are including all of the required information on the reports. <br /> This is a Class II violation. <br /> 317 HSC 25290.1, 25290.2, 25291 Secondary containment not tight. <br /> The July 14, 2015 secondary containment test results indicate a failure at the 91 annular, UDC 5/6, and UDC 9/10. All <br /> secondary containment for the UST system must be tight. Immediately have a properly licensed, trained, and certified <br /> contractor repair or replace the failed component under permit and inspection of the EHD. <br /> This is a Class 11 violation. <br /> 321 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump. <br /> The test boot on the 87 north piping was not pulled back and the valve was pointed straight up. Any potential release <br /> from the primary containment into the secondary containment in the 87 piping does not flow into a collection sump. <br /> All secondary containment systems shall be sloped so that all releases will flow to a collection sump located at the <br /> low point of the underground piping. The boot was pulled back by the technician at the time of inspection. <br /> This was corrected on site. <br /> This is a Class 11 violation. <br /> 323 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br /> The 87 line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of detecting a <br /> 3-gallon per hour leak at 10 psi. Immediately have a properly licensed, trained, and certified contractor repair or <br /> replace the failed leak detector (LG 1 13-x listed, if applicable) and obtain a permit within one business day from the <br /> EHD. If the failed leak detector can't be replaced immediately, there is a possibility that the 87 UST system may be <br /> red tagged to prevent fuel inputs. <br /> This is a repeat violation, Class 11. <br /> Page 5of6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.