My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1789
>
2300 - Underground Storage Tank Program
>
PR0506538
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:24 AM
Creation date
11/8/2018 9:47:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0506538
PE
2361
FACILITY_ID
FA0007486
FACILITY_NAME
COUNTRY MARKETPLACE
STREET_NUMBER
1789
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16337023
CURRENT_STATUS
01
SITE_LOCATION
1789 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\C\CHARTER\1789\PR0506538\COMPLIANCE INFO 2016 - PRESENT.pdf
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
11/18/2016 5:11:43 PM
QuestysRecordID
3261353
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
`•' San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax: (209) 468-3433 Web:www.slgov.or_/q ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> COUNTRY MARKETPLACE 1789 W CHARTER WAY STOCKTON March 08 2016 <br /> On Site Records <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions ■V n R ❑C05 <br /> 202 CCR 2712(b) Failed to maintain cathodic protection test records on site for at least 6 112 years V ❑R in COS <br /> 203 CCR 2712(b) Failed to maintain records of monitoring, repair, lining, and upgrades on site ❑V ❑R n COS <br /> 204 CCR 2712(i) Current monitoring plan approved by the EHD not found on site ■V ❑R ❑COS <br /> 205 CCR 2712(1) Operating permit not on site ❑V n R ❑COS <br /> 206 MSC 25294,25295 Failed to record or report unauthorized release in appropriate time frame ❑V ❑R ❑COS <br /> 207 CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed ■V ❑R in COS <br /> 208 CCR 2715 Designated operator monthly inspection reports not maintained on site for at least 12 months e V ❑R n COS <br /> 209 CCR 2715(f) Designated operator employee training not performed or log not kept ❑V ❑R ❑COS <br /> 210 CCR 2715(f)(2) Unstaffed facility failed to have or implement a training program approved by the EHD o V ❑R ❑COS <br /> 211 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept ❑V ❑R n COS <br /> 212 HSC 25281,5(b)(3) Unburied emergency generator fuel piping not visually inspected at least monthly or log kept ❑V o R COS <br /> UST System Observations <br /> 301 HSC 25292.1 UST system is not operated to prevent unauthorized release, including spills and overfills ❑V n R ❑COS <br /> 302 HSC 25291(b) UST system incapable of detecting leak from primary into secondary containment(pre-Jul 2003) n V ❑R ❑COS <br /> 303 HSC 25290.2(d) Monitoring system not maintained to detect entry into secondary containment(Jul 2003-Jun 2004) ❑V ❑R n COS <br /> 304 HSC 25290.1(d) Monitoring system not maintained to detect entry into secondary containment(after Jul 2044) o V ❑R ❑COS <br /> 305 HSC 25290.1(e) VPH monitoring of the interstitial spaces of the UST system is not maintained ❑V ❑R ❑COS <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity ❑V ❑R n COS <br /> 307 CCR 2632(c) Monitoring system of the interstitial space of a double walled system not maintained ❑V ❑R n COS <br /> 308 CCR 2636(f) Failed to maintain a continuous monitoring system that activates an audible and visual alarm ❑V ❑R n COS <br /> 309 CCR 2636(f)(1) Monitoring in the UDCs failed to activate an audible and visual alarm or stop the flow at the UDC ❑V ❑R ❑COS <br /> 310 CCR 2636(f)(1) Sensor in a turbine sump failed to activate an audible and visual alarm or stop the flow product ❑V o R ❑COS <br /> 311 CCR 2636(f)(5) Piping is not fail-safe outside UDCs or fails to stop flow of product at dispenser inside UDCs ❑V in R ❑COS <br /> 312 CCR 2636 Failed to properly program or operate leak detection equipment n V ❑R ❑COS <br /> 313 CCR 2638(f) Failed to affix a tag sticker on monitoring equipment certified,repaired,or replaced ❑V n R ❑COS <br /> 314 CCR 2631(a) Primary containment not tight(pre-Jul 2003) ❑V n R n COS <br /> 315 HSC 25290.2(c)(1) Primary containment not tight(Jul 2003-Jun2004) ❑V n R ❑COS <br /> 316 HSC 25290.1(c)(1) Primary containment not tight(after Jun 2004) ❑V n R ❑COS <br /> 317 HSC 25290.1,25290.2, Secondary containment not tight ■V :7R ❑COS <br /> 25291 <br /> 318 1 CCR 2636(,) Failed to have secondary containment o V ❑R ❑COS <br /> 319 HSC 25291(e) Water in secondary containment not removed,analyzed,and properly disposed of(pre-Jul 2003) n V D R ❑COS <br /> 320 HSC 25290.1(c3), Secondary containment not constructed to prevent water intrusion ❑V o R ❑COS <br /> 25290.2(c3) <br /> Page 2 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.