My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1789
>
2300 - Underground Storage Tank Program
>
PR0506538
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:24 AM
Creation date
11/8/2018 9:47:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0506538
PE
2361
FACILITY_ID
FA0007486
FACILITY_NAME
COUNTRY MARKETPLACE
STREET_NUMBER
1789
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16337023
CURRENT_STATUS
01
SITE_LOCATION
1789 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\C\CHARTER\1789\PR0506538\COMPLIANCE INFO 2016 - PRESENT.pdf
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
11/18/2016 5:11:43 PM
QuestysRecordID
3261353
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205.6232 <br /> Telephone: (209)468-3420 Fax:(209) 468-3433 Web:www.sjgov,orq/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> COUNTRY MARKETPLACE 1789 W CHARTER WAY STOCKTON March 08 2016 <br /> UST System Observations <br /> 321 CCR 2636(c)(1) All releases in secondary piping do not flow to a coilectior sump n V ,R ■COS <br /> 322 CCR 2636(f)(2) Line leak detector not installed D V ❑R e COS <br /> 323 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi ■V ■R D COS <br /> 324 CCR 2635(b) No spill bucket installed or failed to provide a means to keep it empty ❑V ❑R ❑COS <br /> 325 CCR 2635(b) Spill container failed to contain a minimum capacity of five gallons ■V s R ■COS <br /> 326 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements D V ❑R n COS <br /> 327 CCR 2635(b)(2) Overfill prevention was overridden n V ❑R D COS <br /> 328 HSC 25283.5 Unburied below grade UST failed to meet exemption status ❑V o R ❑COS <br /> 329 CCR 2717.1(g) Tampered with red tag ❑V D R ❑COS <br /> 330 CCR 2717.1(f) Deposited petroleum into a red tagged UST n V o R D COS <br /> 331 HSC 25299(f)(2) Tampered with or disabled leak detection devices or alarms n V ❑R D COS <br /> 332 CCR 2631.1 UST system not compatible with the substance stored n V ❑R o COS <br /> 333 HSC 25298(b) Failed to comply with temporary closure requirements ❑V D R ❑COS <br /> 334 HSC 25298(c) Failed to comply with permanent closure requirements ❑V 7 R ❑COS <br /> Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve V R COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed n V D R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) n V D R COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) ❑V -i R COS <br /> Other Violations <br /> 2010 See below Unlisted AdministratieniDocumentation violation n V _j R -1 COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V n R ❑COS <br /> 2060 See below Unlisted Design/Construction violation n V R ,COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item 4 Remarks <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted. <br /> Financial responsibility documents have not been submitted to the EHD. The financial responsibility documents <br /> submitted for 2015 were actually copies of the 2013 documents with the dates changed and no new, current <br /> signatures. Current financial responsibility documents are required to be submitted annually. Immediately log into the <br /> California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/, and upload the required documents. <br /> This is a repeat violation, Class li. <br /> Page 3 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.