My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005 - 2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
10878
>
2300 - Underground Storage Tank Program
>
PR0231598
>
COMPLIANCE INFO_2005 - 2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:12 PM
Creation date
11/8/2018 9:48:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005 - 2010
RECORD_ID
PR0231598
PE
2361
FACILITY_ID
FA0001146
FACILITY_NAME
MORADA CHEVRON FAST N EASY #60*
STREET_NUMBER
10878
Direction
N
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95212
APN
08607002
CURRENT_STATUS
01
SITE_LOCATION
10878 N HWY 99 E
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\HWY 99\10878\PR0231598\COMPLIANCE INFO 2005 - 2010 .PDF
QuestysFileName
COMPLIANCE INFO 2005 - 2010
QuestysRecordDate
5/17/2017 6:13:49 PM
QuestysRecordID
3384372
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
345
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank Monitoringon-Page 4 • <br /> I. Reporting Format (Check all which apply) <br /> ® This facility will use the Unidocs "Hazardous Materials Monitoring System Inspection Form" to document <br /> inspections (performed at least monthly) of electronic monitoring systems to ensure that they are in proper <br /> working order. <br /> ❑ We will use our own documents to record inspections (performed at least monthly) of electronic monitoring <br /> systems. (Note:A sample copy of each document used must be attached to this monitoring plan) <br /> ❑ A sample copy of each additional UST monitoring form/log used (e.g. alarm logs, MIR forms, etc.) is <br /> attached to this monitoring plan. <br /> ❑ No in-tank leak detection* methods are employed on these tanks as part of required monitoring; or <br /> ❑ Attached to this monitoring plan is a copy of the system set-up report generated by the in-tank leak detection <br /> system. <br /> * (Note: Inventory management is often performed by the same equipment that performs in-tank leak <br /> detection. If you have double-wall tanks, you are not required to include automatic tank gauging as part of <br /> yourformal written monitoringprogram) <br /> J. Training <br /> Copies of the following reference documents are maintained at the facility: (Check any which apply) <br /> ® This Underground Storage Tank Monitoring Plan. <br /> ® Operating manuals for electronic monitoring equipment. <br /> ❑ California Underground Storage Tank Regulations <br /> ❑ State Water Resources Control Board (SWRCB) publication: "Handbook for Tank Owners - Manual and <br /> Statistical Inventory Reconciliation". <br /> ❑ SWRCB publication: "Weekly Manual Tank Gauging for Small Underground Storage Tanks." <br /> ❑ Other (specify): <br /> Facility personnel with UST monitoring responsibilities have been familiarized with all of the above documents <br /> relevant to their job duties. These persons have access to those documents when needed. <br /> Personnel responsible for performing inspections are trained to follow a consistent inspection routine and to <br /> document inspections in an thorough manner. They are trained to distinguish proper equipment function from <br /> obvious hardware or software failures. These personnel have been trained in proper procedures for reporting <br /> alarms, leaks, equipment failure, or other problems. <br /> Personnel responsible for arranging preventive maintenance, servicing, or calibration of monitoring equipment <br /> have sufficient authority to contract such work as may be needed. <br /> Personnel responsible for maintaining UST monitoring records (i.e. logs, test reports, equipment service reports, <br /> etc.) have been instructed that such records must be maintained on-site, available for inspection, for a minimum <br /> of 3 years unless the local agency has indicated otherwise. <br />
The URL can be used to link to this page
Your browser does not support the video tag.