My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
10878
>
2300 - Underground Storage Tank Program
>
PR0231598
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:14 PM
Creation date
11/8/2018 9:48:45 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0231598
PE
2361
FACILITY_ID
FA0001146
FACILITY_NAME
MORADA CHEVRON FAST N EASY #60*
STREET_NUMBER
10878
Direction
N
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95212
APN
08607002
CURRENT_STATUS
01
SITE_LOCATION
10878 N HWY 99 E
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\N\HWY 99\10878\PR0231598\COMPLIANCE INFO 2016 - PRESENT .PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
5/17/2017 4:28:22 PM
QuestysRecordID
3383804
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
208
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• . <br /> SWRCB,January 2002 Page of <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: Tank Manufacturer 1v Industry Standard Professional Engineer <br /> Other(Spec) <br /> Test Method Used: 1 Pressure Cr:Vacuum Hydrostatic <br /> Cl Other(Specify) <br /> Test Equipment Used:mechanical Precision pressure test au a Equipment Resolution:0.1 <br /> Tank#91 n/91s/DSL Tank#87 Tank# Tank# <br /> Is Tank Exempt From Testing?' Yes Y No Yes vi No ❑Yes No Yes 1 No <br /> Tank Capacity: 12,000 12,000 <br /> Tank Material: unknown unknown <br /> Tank Manufacturer: unknown unknown <br /> Product Stored: gasoline/diesel gasoline <br /> Wait time between applying <br /> pressure/vacuum/water and 30 minutes 30 minutes <br /> starting test: <br /> Test Start Time: 10:00am 9:45am <br /> Initial Reading(Rj): 10hg 10hg <br /> Test End Time: 11:00am 10:45am <br /> Final Reading(RF): 10hg 10hg <br /> Test Duration: 60 minutes 60 minutes <br /> Change in Reading(RF-Rj): 0.00hg 0.00hg <br /> Pass/Fail Threshold or Criteria: 0.00hg 0.00hg <br /> Test Result: G Pass ❑Fail I I Pass 1_�Fail Ci Pass f Fail Pass ❑Fail <br /> Was sensor removed for testing? ��Yes ❑No NA �� yes __No NA Yes C!No '_i NA <br /> Yes ❑No '—NA <br /> Was sensor properly replaced and _, Yes _jNo L.NA L4 I <br /> verified functional after testin ? Yes No NA Yes No NA Yes _No J NA <br /> Comments—(include information on repairs made prior to testing, and recommended,follow-trp for.failed tests) <br /> Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. {California Code of Regulations,Title 23,Section 2637(a)(6)1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.