Laserfiche WebLink
i <br /> FRANK ' S ONE STOP FOOD MARTS <br /> UNDERGROUND STORAGE TANK MONITORING PROGRAM <br /> STORE # 4 <br /> Tank monitoring is accomplished with the VEEDER ROOT TLS 2501 <br /> and RED JACKET line leak detectors . This combination provides <br /> continuous monitoring of the storage tanks and the pressurized <br /> piping . Inventory reconciliation is also done to insure the <br /> accuracy of the tank measurements . The TLS 2501 is mounted inside <br /> the door by the front counter• and all equipment was installed by a <br /> manufacturer• authorized representative . <br /> The TLS 250i is equipped with interstitial sensors and a <br /> trench sump sensor . Each tank is equipped with a probe for• liquid <br /> volume measurement . All piping is laid in trenches which drain <br /> back to the monitored sump . In the event of a detected leak the <br /> pumping system is disabled . <br /> Everyday an inventory printout is taken by the employee on <br /> duty and is reconciled by office staff to verify the accuracy of <br /> the system. If discrepancies are found they are immediately <br /> investigated by John Guinta . If John is not available or qualified <br /> for• the job Shaw ' s Maintenance will be brought in to handle the <br /> situation . <br /> Each month John Guinta will open all dispensers and check for• <br /> leaks , all sumps ar•e opened , and leak detectors are checked for• <br /> leaking parts . Checking of the TLS 250i is done by depressing the <br /> Alarm Reset button , if lights of active sensors light system is OK . <br /> In addition , every two weeks the sump sensor• is removed and tested <br /> in water for proper• activation by John Guinta . <br /> John Guinta is responsible for• maintaining monitoring system. <br /> Any problems beyond the scope of his knowledge are addressed by <br /> Shaw ' s Maintenance of Turlock . The manufacturer does not require <br /> regular• maintenance to the system. <br /> Each month as these devices are checked the results will be <br /> recorded by equipment type . All records will be kept at the main <br /> office at 2072 West Yosemite Manteca , California and copies will be <br /> available on site . Inspection reports will be kept showing the <br /> results of the inspection for• each dispenser group , sump holes , <br /> leak detectors , and sump sensor test . <br /> The only training required to operate the TLS 250i is : <br /> When the light and\or• buzzer• sound the attendant on duty needs to <br /> contact John Guinta . <br />