My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4855
>
2300 - Underground Storage Tank Program
>
PR0506650
>
COMPLIANCE INFO_2008-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:12 PM
Creation date
11/8/2018 9:49:59 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2012
RECORD_ID
PR0506650
PE
2361
FACILITY_ID
FA0007571
FACILITY_NAME
ARCH ARCO AM PM*
STREET_NUMBER
4855
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
APN
17926051
CURRENT_STATUS
01
SITE_LOCATION
4855 S HWY 99
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\HWY 99\4855\PR0506650\COMPLIANCE INFO 2008-2012.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
298
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sioov.org/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility Facility <br /> Name; Arch AfCO AM PM Address: 4855 S. Hwy 99, StOCktOn Date:Inspection NOV 30, 2011 <br /> VIOLATIONS <br /> # Ct C2 M Code Section HSC=CA Health and Safe Code;CFR=Code of Federal Regulations <br /> Ci=Class 1 violation;C2=Class 2 violaticn',M=Minor Nolation <br /> Non-Pre` zed Piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1, 1984) (M1) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1,1984) (M1) <br /> Other Violations <br /> 999 Other: I See attached"Continuation—Official Inspection Report'for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> ROUTINE ANNUAL INSPECTION AND MONITORING SYSTEM CERTIFICATION <br /> "Inspection conducted on November 30, 2011. Report completed on December 1, 2011. Checklist left <br /> on site at time of inspection. Violation#302 was added. This report supersedes any previous report. <br /> Class II violations: (204, 311, 313) <br /> 204. On the May 2011 and June 2011 designated operator monthly inspection reports, the designated <br /> operator marked that the secondary containment testing was conducted within the required timeframe. <br /> The secondary containment testing was overdue at the time of both inspections. During the monthly <br /> inspection, the designated operator shall check that all required testing and maintenance for the UST <br /> system have been completed and document the dates they were done. Ensure that designated <br /> operators performing monthly inspections at this facility are including all of the required and correct <br /> information on the reports. <br /> REPEAT VIOLATION <br /> 311. The 87 electronic line leak detector and 91 mechanical line leak failed to detect a leak when tested. <br /> All line leak detectors shall be capable of detecting a 3-gallon per hour leak at 10 psi. The service <br /> technician adjusted the 91 leak detector, retested it, and it passed. Immediately have a properly <br /> licensed, trained, and certified contractor repair or replace the failed 87 leak detector(LG 113-x listed, if <br /> applicable) and obtain a permit within one business day from the EHD. If the failed leak detector can't <br /> be replaced immediately, there is a possibility that the 87 UST system may be red tagged to prevent fuel <br /> inputs. <br /> REPEAT VIOLATION <br /> 313. The 87 and 91 spill containers were observed partially filled with liquid, and failed to have a <br /> minimum capacity of five gallons. All spill containers shall have a minimum capacity of five gallons. <br /> Immediately take all necessary actions to ensure that these containers are capable of a minimum five <br /> gallon capacity. <br /> REPEAT VIOLATION <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> InapeQor. Re BY: Title: <br /> G <br /> EHD 2102 R 9/ /11 Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.