My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4855
>
2300 - Underground Storage Tank Program
>
PR0506650
>
COMPLIANCE INFO_2008-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:12 PM
Creation date
11/8/2018 9:49:59 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2012
RECORD_ID
PR0506650
PE
2361
FACILITY_ID
FA0007571
FACILITY_NAME
ARCH ARCO AM PM*
STREET_NUMBER
4855
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
APN
17926051
CURRENT_STATUS
01
SITE_LOCATION
4855 S HWY 99
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\HWY 99\4855\PR0506650\COMPLIANCE INFO 2008-2012.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
298
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd/unitiii.htmi <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> Facility Facility Inspection Nov 30, 2011 <br /> Name: Arch Arco AM PM Address: 4855 S. Hwy 99, Stockton Date: <br /> Facility Tme: Owner � ) 948-2438 <br /> Contact <br /> Jivtesh Gill <br /> Inspection XRoutine XMonkoring System Certification ri Installation UComplaint-ID# El Other: <br /> Type: <br /> (Authority HSC 25289) Owner <br /> Consentfor. Xlnspedion XSampling XPhotcs Grantedby: aneeP Tim: <br /> Monitoring Piping Overall ❑Mechanical XAudible/visual <br /> Panel Veeder-Root TLS-350 System: XP essurized ❑Suct on ❑Grevty Prevention: <br /> usT 1 2 __ 3 -.-.-.-----.- <br /> -------------- -------------- ------------- ------- <br /> ---product -- -91-octane-- - 89-octane 91- <br /> Designated ICC Ex 12/23/11 Violations: Il M1-Release Detection ❑M2-Release Prevention XM3-Bc1h <br /> Operator. Robert Barnhart Date: <br /> onsite Service Guadalupe Sanchez Icc Few.4/23/13 TTra n9lnrers VR X. 11/8/13 VMI X. 5/20/13 <br /> Technician: p : <br /> VIOLATIONS <br /> HSC=California Heafth and Safet Code;CCR=California Code of R ulations <br /> # C7 C2 M Code Section Cl=Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> Fib Review <br /> 101 HSC 25284 No permit to operate <br /> 102 HSC 25404.5 Annual operating fees not paid <br /> 103 HSC 25284(a)(3) No written agreement between the person that the operating permit was issued to and the tank operator to <br /> monitor the tanks tem <br /> 104 HSC 25292.2 Current financial responsibility documents not on file with the Environmental Health Department(EHD) <br /> 105 CCR 2711 Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form) <br /> 106 CCR 2632(b) Monitoring Program(Monitoring&Response Plans)is not current or approved by the EHD <br /> 107 CCR 2632(d)(1)(C) Not planisite map not submitted or tails to completely show where monitoring is performed <br /> 108 X CCR 2637 Secondary containment:(a)test not performed;(e)test report nZ11tShd within 30 days;(f)test notification <br /> not vided to the EHD at least 48 hours rior to conducting th <br /> Monitonin9 equipment certification:(a)not performed annually; rt not submitted within 30 days: <br /> 109 CCR 2638 (e)test notification not provided to the EHD at least 48 hours pucting an installation,repair, <br /> replacement,calibration,or certification <br /> 110 HSC 252-91(f) Annual line leak detector test not performed (Mt) <br /> --1,1 HSC 25284.2 Annual spill containment testing not performed <br /> 112 CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown ort present (Mtl <br /> 113 CCR 2715(a) Failed to inform the EHD of a change of designated operator ws <br /> 114 CCR 2715(b) Designated operator does not possess a current ICC CA UST System Operator certification <br /> 115 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br /> mtit conditions <br /> 116 HSC 25292.5 Enhanced leak detection(ELD)testing not performed on a system located within 1000'of public well,or <br /> failures not repaired and retested <br /> —i-17 X CCR 2661 Permit to repair UST system not obtained <br /> 118 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br /> 119 HSC 25298(b) Permit to temporarily dose UST system not obtained <br /> 120 HSC 25298(c) Permit to dose UST system not obtained <br /> On Site Records <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6%years,written <br /> performance daims pertaining to release detection systems for 5 years,or records of repairs,linings,and <br /> 201 CCR 2712(b) upgrades for the life of the tank. Monitoring records include:(1)date and time of all monitoring or sampling; <br /> (2)monitoring equipment calibration and maintenance records;(3)results of any visual observations;(4) <br /> results of sample analysis performed a lab or in the field;(5)logs of all readings of gauges or other monitoring <br /> equipment, round water elevations,or other test resuks; 6 results of invento readings and reconciliations <br /> 202 CCR 2712(i) Monitoring plan,response plan,and/or operating permit and all conditions not onsite <br /> Unauthorized release that:(c)did not escape secondary containment and cleaned up within eight hours (Mt) <br /> 203 CCR 2650 was not recorded;(e)escaped secondary containment,not cleaned up after eight hours,or a sudden loss of <br /> product was not re rled to the EHD within 24 hours <br /> Received By: Title: <br /> Inspector. �_ 15 S "• <br /> Stacy Rivera (209) 468-3440 <br /> EHD 23-02 Rev 09/01/11 Page 1 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.