My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4855
>
2300 - Underground Storage Tank Program
>
PR0506650
>
COMPLIANCE INFO_2008-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:12 PM
Creation date
11/8/2018 9:49:59 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2012
RECORD_ID
PR0506650
PE
2361
FACILITY_ID
FA0007571
FACILITY_NAME
ARCH ARCO AM PM*
STREET_NUMBER
4855
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
APN
17926051
CURRENT_STATUS
01
SITE_LOCATION
4855 S HWY 99
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\HWY 99\4855\PR0506650\COMPLIANCE INFO 2008-2012.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
298
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY • <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.s6gov.org/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Farrio Arch Arco AM PM "c"Ity 4855 S. Hwy 99, Stockton oaten°" Nov 30, 2011 <br /> e: <br /> NamAddress: <br /> VIOLATIONS <br /> # Ct C2 M Code Section HSC ,CA CA Hearth and S Code;CFR=Code of Federal Regulations <br /> Ci=Class 1 violation;MRC Gass 2 violation M=Minor violation <br /> On Site Records(continued) <br /> 204 X CCR 2715(c) Designated operator monthly inspection:(1)alarms not documented;(24)spill containers,UDCs,andmps <br /> su <br /> if necessa not inspected; 5 required test dates not checked or noted; 6 em to ee training not verified <br /> 205 CCR 2715(e) Designated operator monthly inspection reports not maintained on site for at least 12 months <br /> 206 CCR 2715(f) Designated operator employee training:(1)not performed;(2)not current for at least one employee on site; <br /> 3 log not kept <br /> 207 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept <br /> Observations <br /> 301 HSC 25292.1 UST system is not operated to prevent unauthorized release,including spills and overfills <br /> 302 HSC 25291(b) UST monitoring system incapable of detecting leak from primary containment into secondary containment(Ml) <br /> 303 CCR 2630(d) UST monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity (Mi) <br /> 304 X CCR 2632(c)(2) Monitoring system is not present in the interstitial space of a double walled UST IMI) <br /> 305 CCR 2636(f)(1) Failed to maintain a continuous monitoring system for underground piping&UDCs that activates an (Mi) <br /> audible and visual alarm or stops flow of pmduct at the dispenser when it detects a leak <br /> 306 X CCR 2631(a) Primary containment is not product tight <br /> 307 X HSC 25291(a)(2) Secondary containment for UST system is not tight <br /> 308 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump <br /> 309 CCR 2636(a) Failed to have secendary containment for piping(indudes conventional suction piping) (M2) <br /> 310 HSC 25291(a) Water in 2-containment not removed,analyzed&properly disposed of <br /> 311 X CCR 2636(f)(2) Line leak tletector(s)not installed or failed to detect a 3-gallon per hour leak at 10 psi (Mi) <br /> 312 CCR 2635(b) No spill container or overfill prevention system installed IM2) <br /> 313 X CCR 2635(b)(1) Spill container failed to contain a minimum cepacity,of five gallons,or failed to provide a means to keep (M2) <br /> the spill container em <br /> 314 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet ovefill requirements IM21 <br /> 315 HSC 25299(f)(2) Tampering with or disabling leak detection devices or alarms <br /> 316 CCR 2631.1(a) UST system is not compatible with the substance$foretl <br /> 317 1 HSC 25298(a) Illegally abandoned UST system <br /> AB 1702(2003-2004) HSC 25290.1(installed between 07101/03 and 06130104) <br /> VPH System HSC 25290.1 installed on or after 07101104 <br /> Compatibility and permeability requirements:(a)UST system is not compatible with the substance stored;(b) <br /> 401 CCR 2631.1 results of the compatibility and permeability testing requirements listed in subsections CCR 2631(b)and(d) <br /> for a UST system installed after July 1,2004,were not submitted <br /> 402 HSC 25290.1(c)(1) Primary containment not liquid or vapor tight <br /> HSC 25290.2(c)(1) <br /> 403 HSC 25-290 1(c)(2) Secondary containment not liquid or vapor tight <br /> HSC 25290.2(c)(2) <br /> 404 HSC 25290.1(c)(3) Secondary containment not constructed to prevent water intrusion <br /> HSC 25290.2(c)(3) <br /> 405 HSC 25-290 1(d) Monitoring system not maintained to detect water he se on into the secondary containment,or the entry of <br /> HSC 25290.2 d liquid or vapor from the rima containment into the secondary containment <br /> 406 HSC 25280.1(e) Interstitial liquid measurement method,constant vacuum,or constant pressure in the interstitial space of the <br /> UST s tem not maintained <br /> 407 HSC 25290.10) UST system not tested by one of the following methods prior to use:(1)Enhanced leak detection;(2)inert gas <br /> HSC 25290.2 i ressure testa roved b SWRCB; 3 test method deemed equivalent to 1 or 2 b me SWRCB <br /> Emergency Generator Systems <br /> Eigm <br /> 36(f)(6) Emergency generator monitoring system not checked daily or log not kept if no leak detector IMt) <br /> 81.5(b)(3) Unburied fuel piping not visually inspected al least monthly or log not kept (sl <br /> USTs in a Vault <br /> 283.5(a)(1) All exterior surfaces of the tank and connected piping cannot be directly viewed <br /> 283.5(a)(2) Structure that the UST is located in does not provide for secondary containment <br /> 283.5(a)(3) Failed to conduct weekly UST inspections or maintain a log of weekly inspections <br /> 283.5(a)(5) UST installed after July 1,2003,does not meet or exceed applicable sections of HSC 25291 <br /> Non-Pressurized Piping <br /> 43(d) Daily monitoring of suction piping(pre-January 1,1984)not performed IM11 <br /> Inepedar Rexived Eh' TIUe: <br /> Stacy Rivera (209) 468-3440 ,9 <br /> REPORT <br /> EHD 2&02 Rev 09/01111 Page 2 UST INSPECTION <br />
The URL can be used to link to this page
Your browser does not support the video tag.