My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2006-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
3515
>
2300 - Underground Storage Tank Program
>
PR0231210
>
COMPLIANCE INFO 2006-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 1:54:23 PM
Creation date
11/8/2018 9:50:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2015
RECORD_ID
PR0231210
PE
2361
FACILITY_ID
FA0003747
STREET_NUMBER
3515
STREET_NAME
NAVY
STREET_TYPE
Dr
City
Stockton
Zip
95203
APN
161-030-02
CURRENT_STATUS
01
SITE_LOCATION
3515 Navy Dr
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\NAVY\3515\PR0231210\COMPLIANCE INFO 2006-2015.PDF
QuestysFileName
COMPLIANCE INFO 2006-2015
QuestysRecordDate
8/4/2017 7:52:05 PM
QuestysRecordID
3555178
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
297
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TS7393-05 • • Page_2—of—4- <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: ❑ Tank Manufacturer 0 Industry Standard ❑Professional Engineer <br /> ❑ Other(Specify) <br /> Test Method Used: ❑Pressure ® Vacuum ❑Hydrostatic <br /> ❑ Other(Specify) <br /> Test Equipment Used: DIGITAL MANOMETER Equipment Resolution: <br /> Tank#RECLAIM Tank# Tank# Tank# <br /> Is Tank Exempt From Testing?' ❑Yes ®No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑ No <br /> Tank Capacity: 6000 GALLON <br /> Tank Material: FB3ERGLASS <br /> Tank Manufacturer: OWENS CORNING <br /> Product Stored: RECLAIM LIQUIDS <br /> Wait time between applying <br /> pressure/vacuum/water and 15 MIN <br /> starting test: <br /> Test Start Time: N/A <br /> Initial Reading(114): N/A <br /> Test End Time: N/A <br /> Final Reading(RF): N/A <br /> Test Duration: 1 HOUR <br /> Change in Reading(RF-R): N/A <br /> Pass/Fail Threshold or Criteria: N/A <br /> Test Result: ❑ Pass ❑ Fail ❑ Pass ❑Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> Was sensor removed for testing? ❑Yes ONO ❑NA ❑Yes ❑No ❑NA ❑Yes❑No [INA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and ❑Yes ❑No ®NA ❑Yes ❑No ❑NA ❑Yes❑No ❑NA ❑Yes ❑No ❑NA <br /> verified functional after testing? <br /> Comments— (include information on repairs made prior to testing and recommended follow-up for jailed tests) <br /> RECLAIM TANK ANNULAR COULD NOT BE TESTED DUE TO THE RONAN ANNULAR SENSOR <br /> NOT BEING ABLE TO BE REMOVED. THE REPAIR OF THE ANNULAR SENSOR IS CURRENTLY <br /> IN PERMIT STATUS AS OF 23 OCT 2006 TO BE REPLACED. TESTING OF ANNULAR SPACE CAN <br /> BE PERFORMED AT THAT TIME. <br /> rwG <br /> Secondary containme the continuous monitoring automatically monitors both the primary and secondary <br /> containment such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> fnetinrt f!`olifnrnio r1M.of Anmdotinne Titlo 7Z Ccrtinn 141W.VA.1l <br />