3515
>
2300 - Underground Storage Tank Program
>
PR0231210
>
COMPLIANCE INFO 2006-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 1:54:23 PM
Creation date
11/8/2018 9:50:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2015
RECORD_ID
PR0231210
PE
2361
FACILITY_ID
FA0003747
STREET_NUMBER
3515
STREET_NAME
NAVY
STREET_TYPE
Dr
City
Stockton
Zip
95203
APN
161-030-02
CURRENT_STATUS
01
SITE_LOCATION
3515 Navy Dr
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\NAVY\3515\PR0231210\COMPLIANCE INFO 2006-2015.PDF
QuestysFileName
COMPLIANCE INFO 2006-2015
QuestysRecordDate
8/4/2017 7:52:05 PM
QuestysRecordID
3555178
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
297
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TS7393-05 • • Page—4—of—4- <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: ❑ Sump Manufacturer S Industry Standard ❑Professional Engineer <br /> ❑ Other(Specify) <br /> Test Method Used: ❑Pressure ❑ Vacuum S Hydrostatic <br /> ❑ Other(Specify) <br /> Test Equipment Used: INCON TS-STS TEST UNIT Equipment Resolution: <br /> Sump#PIPING Su NSITION Sump# Sump# <br /> Sump Diameter: 44 INCHES 36 INCHES <br /> Sump Depth: 74 INCHES 50.5 INCHES <br /> Sump Material: FIBERGLASS FIBERGLASS <br /> Height from Tank Top to Top of 30 INCHES 40 INCHES <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 27 INCHES 38 INCHES <br /> Electrical Penetration: <br /> Condition of sump prior to testing: POOR GOOD <br /> 2"ABOVE HIGHEST 2"ABOVE HIGHEST <br /> Portion of Sump Tested' <br /> PIPING PENETRATION PIPING PENETRATION <br /> Does turbine shut down when <br /> SUMP sensor detects liquid(both ❑Yes ❑No SNA ❑Yes ❑No S NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> product and water)?* <br /> Turbine shutdown response time N/A N/A N/A N/A <br /> Is system programmed for fail-safe ❑Yes ❑No S NA ❑Yes ❑No SNA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> shutdown? <br /> Was fail-safeverified to be <br /> operational? ❑Yes ❑No SNA ❑Yes ❑No SNA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Wait time between applying <br /> pressure/vacuum/water and starting 15 MIN 15 MIN <br /> test: <br /> Test Start Time: N/A N/A 10:38 10:55 <br /> AM AM <br /> Initial Reading(111): N/A N/A 5.8219 5.8219 <br /> 10:5Test End Time: N/A N/A AM M AM <br /> AAM <br /> Final Reading(RF): N/A N/A 5.8219 5.8216 <br /> Test Duration: 15 MIN 15 MIN 15 MIN 15 MIN <br /> Change in Reading(RF-R�: N/A N/A .0000 .0003 <br /> Pass/Fail Threshold or Criteria: N/A N/A .002 .002 <br /> Test Result: ❑ Pass ❑Fail S Pass ❑ Fail ❑ Pass ❑Fail ❑ Pass ❑Fail <br /> Was sensor removed for testing? ❑Yes S No ❑NA S Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and ❑Yes S No ❑NA I S Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> verified functional after testing? <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> PIPING SUMP (LOCATED ON TANK PAD) COULD NOT BE HYDROSTATICALLY TESTED DUE <br /> TO A BAD SECONDARY TEST BOOT. BOOT WILL NEED TO BE REPAIRED/REPLACED IN <br /> ORDER TO PERFORM TEST. <br /> TRANSITION SUMP PASSED-NO REPAIRS ARE NEEDED AT PRESENT TIME. <br /> rrea <br />