San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209) 468-3433 Web:www.sioov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> 7-ELEVEN INC#17334 4501 N PERSHING AVE, Stockton October 05, 2016 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 203 CCR 2712(b) Failed to maintain records of monitoring, repair, lining, and upgrades on site. <br /> Records of the tank annular secondary containment testing for the UST system performed on 12/1/15 were not <br /> found on site. These records shall be kept on site for the life of the tank. Immediately locate and maintain these <br /> records on site and submit copies to the EHD. <br /> This is a repeat violation, Class Il. <br /> 205 CCR 2712(1) Failure to have an approved UST response plan available onsite. <br /> The response plan that is found on site is not current and/or not approved by the Environmental Health Department <br /> (EHD). The response plan found in the California Environmental Reporting System (CERS) is current. Ensure that <br /> a copy of the current Response Plan is available on site for inspection at any time. <br /> This is a minor violation. <br /> 302 HSC 25291(b) UST system incapable of detecting leak from primary into secondary containment(pre-Jul 2003). <br /> The 91-product annular sensor failed to go out of alarm when tested. The interstitial space shall be monitored with <br /> a monitoring system connected to an audible and visual alarm system. The sensor was replaced and retested <br /> during the inspection. A"UST Retrofit Verification with Inspector Already Onsite" form has been completed and <br /> provided to the operator and contractor. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br /> The 91-product submersible turbine pump (STP) sump 208 sensor was found leaning over and not positioned to <br /> detect a leak at the earliest opportunity. Monitoring equipment shall be maintained to be able to detect a leak at the <br /> earliest possible opportunity. The service technician placed the 91-product STP sump 208 sensor in an upright <br /> position after completing the testing. <br /> This was corrected on site. <br /> This is a repeat violation, Class Il. <br /> 315 HSC 25291(e) Water in secondary containment not removed, analyzed, and properly disposed of(pre-Jul 2003). <br /> Liquid was observed in the 91-product submersible turbine pump (STP) sump. If water could enter into the <br /> secondary containment by precipitation or infiltration, it must be removed and disposed of properly. The service <br /> technician removed the liquid from the 91-product STP sump. Ensure that the 91-product STP sump is maintained <br /> free of liquid. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by November 4, 2016. <br /> FA0002479 PR0231233 SC001 10/05/2016 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 5 Underground Storage Tank Program OR <br />