My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2004 - 2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PESCADERO
>
1535
>
2300 - Underground Storage Tank Program
>
PR0232495
>
COMPLIANCE INFO 2004 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2023 1:44:43 PM
Creation date
11/8/2018 9:52:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004 - 2007
RECORD_ID
PR0232495
PE
2361
FACILITY_ID
FA0003854
FACILITY_NAME
YRC INC
STREET_NUMBER
1535
Direction
E
STREET_NAME
PESCADERO
STREET_TYPE
Ave
City
Tracy
Zip
95304
APN
21306026
CURRENT_STATUS
01
SITE_LOCATION
1535 E Pescadero Ave
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\P\PESCADERO\1535\PR0232495\COMPLIANCE INFO 2004 - 2007.PDF
QuestysFileName
COMPLIANCE INFO 2004 - 2007
QuestysRecordDate
12/6/2016 12:58:59 AM
QuestysRecordID
3271591
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
339
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
U <br />D. Results of Testing/Servicing <br />Software Version Installed: 329687-OOIA/329688-002 <br />Complete the following checklist: <br />aJ <br />® Yes <br />❑No <br />Is the audible alarm operational? <br />® Yes <br />❑No <br />Is the visual alarm operational? <br />® Yes <br />❑No <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />N Yes <br />❑No <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br />not interfere with their proper operation? <br />7 Yes <br />❑No <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) operational? <br />NN/A <br />❑ Yes <br />❑No <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />NN/A <br />monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br />positive shut down? (Check all that apply) ❑ Sump/Trench Sensors; ❑ Dispenser Containment Sensors. <br />Did Von confirm positive shut down due to leaks and sensor failure/disconnection? ❑ Yes; ❑ No. <br />❑ Yes <br />[]No <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br />NN/A <br />mechanical overfill prevention valve is installed), is the over -fill warning alarm visible and audible at the tank <br />fillpoint(s) and operating ro erl ? If yes, at what percent of tank capacity does the alarm trigger? % <br />❑Yes <br />NNo <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br />and list the manufacturer name and model for all replacement parts in Section E, below. <br />❑Yes <br />NNo <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) ❑ <br />Product; ❑ Water. If yes, describe causes in Section E, below. <br />N Yes <br />❑ No <br />Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable <br />❑ Yes <br />N No* <br />Is all monitoring equipment operational per manufacturer's specifications? <br />In Section E below, describe how and when these deficiencies were or will be corrected. <br />E. Comments: <br />1 -THE DIESEL IS PRESSURIZED BUT HAS NO LLD OR PSD. <br />2 -THE SOAP TANK HAS NO TLM AND THE ANNULAR SENSOR IS NOT PULLED AROUND THE TANK. THE INSPECTOR <br />HAS A PERMIT FOR REPAIRS AND IS AWARE OF THE PROBLEM. <br />3 -TANKS #2 AND #4 HAVE NO PULL STRINGS ON THE SENSOR'S THERE IN PLACE BY A WIRE. <br />4- NO ALARM HISTORY PAST DEC.27-04 ON UNIT #1, UNIT HAD TO BE REPROGRAMED BY CONTRACTOR DOING <br />WORK AT SITE. <br />5 -SECONDARY BOOT ON THE WASTE FUEL TANK # 5 CAN NOT BE PULLED BACK, ITS GLUED IN PLACE. <br />6- ANNULAR SENSOR ON TK -2 WAS SITTING ON TOP OF THE TANK, AND THE WIRE USED TO FEED THE <br />SENSOR DOWN WAS GONE THAT WAS INSTALLED IN MARCH OF 04. <br />* ALL SENSORS FUNCTION NORMALY BUT ANNULAR SENSOR ON SOAP TANK PROHIBITS CERTIFICATION OF <br />SYSTEM. <br />Page 2 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.