Laserfiche WebLink
MONIARING SYSTEM CERTIFMATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7,Health and Safety Code; Chapte-16, Vii,,,^inn 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitor:-; equipment. A separate certification or report must be <br /> prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to <br /> the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems <br /> within 30 days of test date. <br /> A. General Information <br /> FacilityName: Fast Lane-Lathrop (Auto) Bldg.No. — <br /> Site Address: 116 E Roth Road City: Lathrop, CA Zip: 95330 <br /> Facility Contact Person: Hardeep Gill Contact Phone No: 707-326-0369 <br /> Make/Model of Monitoring System: VR - 350 Date of Testing/Servicing: 5/23/2011 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment ins ected/mrviced: <br /> Tank 1D:_1 — 87 Tank M: 3 — Diesel <br /> Z In-Tank Gauging Probe. Model: MAG-7 01n-Tank Gauging Probe. Model: MAG-7 <br /> Z Annular Space or Vault Sensor. Model: 303 0 Annular Space or Vault Sensor. Model: 303 <br /> 0 Piping Sump/Trench Sensor(s). Model: 208 Ed Piping Sum,:/Trench Sensor(s). Model: 208 <br /> Z Fill Sump Sensor(s). Model: 208 0 Fill�: :p Sensor(s). Model: 208 <br /> Z Mechanical Line Leak Detector. Model: 99LD2000 Z Meenanical Line Leak Detector. Model: STP-MLD-D <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> 3 Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> Z Other(specify equipment type and model in Section E on Page 2). j ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: 2 - 91 Tank ID: <br /> Z In-Tank Gauging Probe. Model: MAG-7 ❑ In-Tank Gauging Probe. Model: <br /> Z Annular Space or Vault Sensor. Model: 303 3 Annular Space or Vault Sensor. Model: <br /> Z Piping Sump/Trench Sensor(s). Model: 208 ❑ Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: <br /> Z Fill Sump Sensor(s). Model: 208 ❑ Mechanical Line Leak Detector. Model: <br /> Z Mechanical Line Leak Detector. Model: 99LD2000 13 Electronic Line Leak Detector. Model: <br /> i3 Electronic Line Leak Detector. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> 13 Tank Overfill/High-Level Sensor. Model: 13 Other(specify equipment type and model in Section E on Page 2). <br /> Z Other(specify equipment t e and model in Section E on Page 2). <br /> Dispenser ID: 1 / 2 Dispenser ID: 7 / 8 <br /> Z Dispenser Containment Sensor(s). Model: 208 Z Dispenser Containment Sensor(s). Model: 208 <br /> Z Shear Valve(s). Z Shear Valve(s). <br /> D Dispenser Containment Float(s)and Chain(s). r't Dis -user Containment Floats and Chains . <br /> Dispenser ID: 3 / 4 Disperser ID: 9 / 10 <br /> Z Dispenser Containment Sensor(s). Model: 208 Z Dis; user Containment Sensor(s). Model: 208 <br /> Z Shear Valve(s). Z Shear Valve(s). <br /> ❑ <br /> Dispenser Containment Floa s and Chain(s). ❑ Dis enser Containment Floats and Chain (s). <br /> Dispenser ID: 5 / 6 Dispenser ID: 11 / 12 <br /> Z Dispenser Containment Sensor(s-). Model: 208 Z Dispenser Containment Sensor(s). Model: 208 <br /> Z Shear Valve(s). Z Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). 3 Dis enser Containment Float(s) and Chain (s). <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br /> manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this <br /> information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br /> reports,I have also attached a copy of the report; (check all that apply): © System sett-up ❑X Alarm <br /> history report <br /> Technician Name(print): AI Milburn Signature: �Z_1z2 <br /> Certification No: A27843 License.No. 956953 <br /> Testing Company Name: EPIC Compliance Systems Inc. Phone No. 888-700-EPIC <br /> Testing Company Address: 1435 Huntington Ave, Suite 230 <br /> South San Francisco, CA 94080 Date of Testing/Servicing: 5/23/2011 <br /> UN-036-1/4 Pagel of 5 Rev.06/04/01 <br /> www.unidocs.org <br />