Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www sicov orD/ehd/unitiii.htmi <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Facility address: Inspection Date: <br /> Fast Lane Central Valley 116 East Roth Road, Lathrop May 23, 2011 <br /> VIOLATIONS R <br /> # CodeSection HSC=CA Health&Safet Code:CCR=CA Code of Regulations;V=Violation RV=Re eat Violation V V <br /> Designated operator monthly inspection:(c)(1)alarms not documented;(c)(24)spill containers, <br /> 23c CCR 2715(c), (e) UDCs,and sumps(if necessary)not inspected; (c)(5)required test dates not checked or noted;(c)(6) <br /> employee training not verified; (e)monthly inspection reports not maintained on site for at least 12 <br /> months <br /> 23d CCR 2715(f) Designated operator employee training: (1)not performed;(2)not current for at least one employee X <br /> on site 3 log not kept <br /> Monitoring equipment certification: (a)not performed annually; (d)test report not submitted within 30 <br /> 24 CCR 2638 days;(e)test notification not provided to the EHD at least 48 hours prior to conducting an installation, <br /> repair, replacement, calibration,or certification; (f)performed,and failed to affix a tag/sticker on each <br /> monitoring equipment com onent that was certified repaired,or replaced <br /> 25 HSC 25291 Annual line leak detector test not performed M7 <br /> 26 HSC 25284.2 Annuals ill containment testing not performed <br /> 27 CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present M7 <br /> 28 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to permit (M2) <br /> conditions <br /> 29 CCR 2643(e) Biennial tightness test of gravity pipingnot performed -January 1 1984 M7 <br /> 30 CCR 2643(d) Triennial line test for conventional suction piping not performed re-Janus 1 1984 M7 <br /> 31 HSC 25292.5 ELD testing not performed on a system located within 1000'of public well,or failures not repaired and <br /> retested <br /> 32 CCR 2661 Permit to repair UST system not obtained X <br /> 33 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br /> 34 HSC 25298(b) Permit to temporarily close UST system not obtained <br /> 35 HSC 25298(c) Permit to close UST system not obtained <br /> 36 HSC 25299(f)(2) Tampering with or disabling leak detection devices or alarms <br /> 37 HSC 25298(a) Illegally abandoned UST system <br /> 38 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept <br /> 39 CCR 2631.1 a UST system is not compatible with the substance stored <br /> Emergency enerator systems <br /> 40 CCR 2636 6 Eme encgenerator monitoringsystem not checked dailyor to not kept if no leak detector M7 <br /> 41 HSC 25281.5 b 3 Unburied fuel i in not visual/ ins ected at least monthly or log not kept M7 <br /> AS 1702(2003-2004) HSC 25290.2(installed between 07/01/03 and 06130/04) <br /> VPH Systems HSC 25290.1 installed on or after 07/01/04 <br /> Compatibility and permeability requirements:(a)UST system is not compatible with the substance <br /> 42 FCCR stored;(b)results of the compatibility and permeability testing requirements listed in subsections CCR <br /> 2631 b and d for a UST system installed after July 1 2004 were not submitted <br /> JH <br /> 25290.1(c)(1) Primary containment not liquid or vapor tight X <br /> 25290.2(c)(1) <br /> 25290.1(c)(2) Secondary containment not liquid or vapor tight <br /> 25290.2 c 2 <br /> 25290.1(c)(3) Secondary containment not constructed to prevent water intrusion <br /> 25290.2(c)(3) <br /> 25290.1(d) Monitoring system not maintained to detect water intrusion into the secondary containment,or (M7) <br /> 25290.2 d the entryof liquid or vapor from the rima containment into the seconds containment <br /> 25290.1(e) Interstitial liquid measurement method, constant vacuum,or constant pressure in the interstitial (M7) <br /> s ace of the UST s stem not maintained <br /> 25290.10) UST system not tested by one of the following methods prior to use:(1)Enhanced leak detection; (2) <br /> 25290.2(1) inert gas pressure test approved by SWRCB;(3)test method deemed equivalent to(1)or(2)by the <br /> SWRCB <br /> Other violations <br /> r See attached"Continuation—Official Ins ection Re ort"for violation(s)not listed above. <br /> EHD inspector Phone: UIC <br /> (209) 468-8257 septic system: <br /> ❑Serves z20 people/day <br /> Received by: Tine: C Receives other than sanitary waste <br /> ^„ , �� Other disposal methods: <br /> C Dry wells/French Drains <br /> EHD 23-02-002 REVjWA10 Page 2 UST INSPECTION REPORT <br />