My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
116
>
2300 - Underground Storage Tank Program
>
PR0523684
>
COMPLIANCE INFO 2010 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:16 PM
Creation date
11/8/2018 9:53:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2012
RECORD_ID
PR0523684
PE
2351
FACILITY_ID
FA0015977
FACILITY_NAME
Fast Lane Central Valley
STREET_NUMBER
116
STREET_NAME
ROTH
STREET_TYPE
Rd
City
Lathrop
Zip
95330
APN
196-02-020
CURRENT_STATUS
01
SITE_LOCATION
116 Roth Rd
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\R\ROTH\116\PR0523684\COMPLIANCE INFO 2010 - 2012.PDF
QuestysFileName
COMPLIANCE INFO 2010 - 2012
QuestysRecordDate
4/25/2018 3:57:18 PM
QuestysRecordID
3867065
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
535
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ' ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.s'Qov.orci/ehd/uniflii.html <br /> CONTINUATION FORM Page: 5 of 5 <br /> OFFICIAL INSPECTION REPORT Date: 10/27/10 <br /> Facility Address: Fast Lane Central Valley LLC 116 East Roth Rd, Lathrop Program: UST <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II orMINOR-Notice to Com I <br /> Truck side UST Inspection: Routine and Annual Monitoring System Certification. All Repeat Violations <br /> 22 continue. after detection. A copy Reportable Release Report will but submitted to SJC EHD by <br /> 11/29/10 in lieu of Recordable Release Report if cleanup is not done within 8 hours. <br /> 23c. The Designated Operator failed to document a response action for or check that they were <br /> responded to appropriately on the 02/26/10 designated operator monthly inspection report. DO stated <br /> "L5 Diesel South Fill Sump is currently in alarm" regarding the fuel alarm on 01/21/10. There were no <br /> work orders or response action for the L5 fuel alarm found. During the monthly inspection, the <br /> designated operator shall review the alarm history for the previous month, check that each alarm was <br /> documented and responded to appropriately, and attach a copy of the alarm history with documentation <br /> taken in response to any alarms to the monthly report. Ensure that DO performing monthly inspections <br /> at this facility are including all of the required information on the reports. <br /> 43, 44. All diesel dispensers have weeping at the union above the shear valve piping. All the under <br /> dispenser pans has what appears to be diesel fuel: Disp 18a -wet, small liquid amounts, dark <br /> appearance; Disp 17a - damp moisture; Disp 16a -wet, small liquid amounts; Disp 15a -wet, small <br /> liquid amounts, light appearance; Disp 14a-wet, one inch of liquid, fuel odor. Diesel fuel was found in <br /> the Diesel North and South STP sump. All primary containment must be impervious to the liquid and <br /> vapor of the substance contained. All secondary containment shall be impervious to the liquid and vapor <br /> of the substance contained and constructed to prevent structural weakening as a result of contact with <br /> any hazardous substances released from the primary containment. Immediately have a properly <br /> licensed, trained, and certified contractor find the source of the leak and replace or repair the failed <br /> equipment. A permit and inspection of the EHD maybe required. If the failed component can't be <br /> replaced immediately, there is a possibility that the Diesel North and South UST system may be red <br /> tagged to prevent fuel inputs. <br /> Submit to SJC EHD within 30 days (11/29/10): 1. one copy of the completed "Return to Compliance <br /> Certification" form 2. a written corrective action statement for the above violations 3. requested/ <br /> supporting documentations <br /> Note: A partial annual Monitoring System Certification (MSC) was performed on 10/27/10. 1-1-1-24 <br /> sensors were completed. Technician was unable to complete testing of the smart sensors (S1-S4). A <br /> complete MSC testing due due by end of October 2010. Immediately schedule to finish the MSC testing <br /> and provide 48 hours notification to the EHD. Please be aware that a follow up inspection will be <br /> charged at our current hourly rate, different rate of charge if testing performed on weekend. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WI BE BILLED AT THE CURRENT HOURLY RATE($122). <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY ME EHD'S CURRENT HOURLY RATE. <br /> EHD or: Recei Title: <br /> J <br /> EH 2-003 08/10110 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.