Laserfiche WebLink
MONITOVG SYSTEM CERTIFIC:TION <br /> CERTIFICATION / TEST DATE: February 17, 2010 <br /> At. FACILITY A2. OWNER <br /> Name Fast Lane Lathrop <br /> Name Christina Gill <br /> Address 116 E.Roth Road,Lathrop,CA 95330 Address 111 Healdsburg Avenue,Healdsburg,CA 95448 <br /> Phone# 707-431-0541 <br /> Phone# 707-431-0541 Contact Christina Gill <br /> Contact Christina Gill <br /> D. RESULTS OF TESTING 1 SERVICING <br /> Make / Model of Monitoring System: Veeder-Root TLS-350 <br /> Software Version Installed: 327.04 <br /> Complete the following checklist: _ <br /> ■ Yes ❑ No* Is the audible alarm o erational7 <br /> ■ Yes ❑ No* Is the visual alarm operational? <br /> ❑ Yes ❑ No* Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> ❑ Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br /> will not interfere with their proper operation? <br /> r-1Yes ❑ No* If alarms are relayed to a remote monitoring station,Is all communications equipment(e.g.modems) <br /> ❑ N/A operational? _ <br /> ❑ Yes ❑ No' For pressurized piping systems,does the turbine automatically shut down If the piping secondary containment <br /> ❑ NIA monitoring system detects a leak,fails to operate,or is electrically disconnected? If yes:which sensors initiate <br /> positive shutdown7 (check all that apply) ❑ SumPlTrench sensors; ❑ Dispenser Containment Sensors. <br /> ❑ Yes ❑ No* Did you confirm positive shut-down due to leaks and sensor failureldisconnection? <br /> ❑ Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.no <br /> ❑ N/A mechanical overfill prevention valve is installed),is the overfill warning alarm visible and audible at the tank <br /> fill point(s)and operating properly? If so,at what percent of tank capacity does the alarm trigger? % <br /> ❑ Yes* ■ No Was any monitoring equipment replaced? If yes,Identify specific sensors,probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E,below. <br /> ❑ Yes* ❑ No Was any liquid found inside any secondary containment systems designed as dry systems? <br /> (Check all that apply) ❑ Product; ❑ Water. If yes,describe causes in Section E,below. <br /> ■ Yes ElNo* Was monitoring system set-up reviewed to insure prpper settingsf applicable. <br /> ? Attach set-up reports,i <br /> ■ Yes ❑ No* Is all monitoring equipment operational per manufacturer's specifications? <br /> - In Section E below, describe how and when these deficiencies were or will be corrected. <br /> E. COMMENTS <br /> ©zoos Walton Engineedng,inc. Page 2 of 3 <br />