Laserfiche WebLink
MONITOFWNG SYSTEM CERTIFIC:TIUN <br /> CERTIFICATION / TEST DATE: February 17, 2010 <br /> A2. OWNER <br /> Al. FACILITY Name Christina Gill <br /> Name Fast Lane Lathrop <br /> Address 116 E.Roth Road,Lathrop,CA 95330 Address 111 Healdsburg Avenue,Healdsburg,CA 9544 <br /> Phone# 707-431-0541 <br /> Phone# 707-431-0541 Contact Christina Gill <br /> Contact Christina Gill <br /> F. IN-TANK GAUGING 1 SIR EQUIPMENT: ■ Check this box if tank gauging is used only for inventory control. <br /> ❑ Check this box if no tank gauging or SIR equipment Is installed. <br /> This section must be completed if in-tank gaugung equipment is used to perform leak detection monitoring. <br /> complete the following checklist: <br /> ❑ Yes ❑ No" Has all Input wiring been Inspected for proper entry,and termination,including testing for ground faults? <br /> ❑ Yes ❑ No were all tank gauging probes visually inspected for damage and residue buildup? <br /> ❑ Yes ❑ No*� Was accuracy of system product level readings tested? <br /> ❑ Yes ❑ No* Was accuracy of system water level readings tested? <br /> ❑ Yes ❑ No* Were all probes reinstalled properly? <br /> cklist completed? <br /> ❑ Yes ❑ No' Were all items on the equipment manufacturer's maintenance che <br /> * In Section H below, describe how and when these deficiencies were or will be corrected. <br /> G. LINE LEAK DETECTORS (LLD): <br /> ❑ Check this box if LLDs are not installed. <br /> Complete the following checklist: <br /> ■ Yes ❑ No* For equipment start-up or annual equipment certification,was a leak simulated to verify LLD performance? <br /> ❑ NIA (check all that apply) Simulated leak rate: ■ 3 g.p•h•, 1-10.1 g.P•h.; ❑ 0.2 g.P•h. <br /> ■ Yes ❑ No* Were all LLDs confirmad operational antl accurate within regulatory requirements? <br /> ■ Yes ❑ No* Was the testing apparatus properly calibrated? <br /> ■ Yes ❑ No* For mechanical LLDs,does the LLD restrict product flow if it detects a leak? <br /> ❑ NIA <br /> ❑ Yes ❑ No* For electronic LLDs,does the turbine automatically shut off if the LLD detects a leak? <br /> ■ NIA <br /> disabletl <br /> ❑ Yes ❑ No* <br /> For electronic LLOs,does the turbine automatically shut off if any portion of the monitoring system is <br /> ■ NIA or disconnected? <br /> ❑ Yes ❑ No* For electronic LLDs,does the turbine automatically shut off if any portion of the monitoring system malfunctions <br /> ■ NIA or fails a testi <br /> ❑ Yes ❑ No" For electronic LLDs,have all accessible wiring connections been visually inspected? <br /> ■ NIA <br /> ■ Yes ❑ No* Were all items on the equipment manufacturer's maintenance checklist completed? —— <br /> * In Section H below, describe how and when these deficiencies were or will be corrected. <br /> H. COMMENTS <br /> © <br /> 2006 Walton Engineering,Inc. Page 3 of 3 <br />