PE
2351
FACILITY_ID
FA0015977
FACILITY_NAME
Fast Lane Central Valley
STREET_NUMBER
116
STREET_NAME
ROTH
STREET_TYPE
Rd
City
Lathrop
Zip
95330
APN
196-02-020
CURRENT_STATUS
01
SITE_LOCATION
116 Roth Rd
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\R\ROTH\116\PR0523684\INSTALL 2006.PDF
QuestysFileName
INSTALL 2006
QuestysRecordDate
4/24/2018 10:24:48 PM
QuestysRecordID
3865777
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
403
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t <br /> Features <br /> —g— <br /> ique Spill Bucket Mounting Ring- FillNapor Ports-Configurations are groove Raintight(RT)design and the <br /> :i bolt holes outside the ring, removes available to accommodate a single fill watertight Sealable Cover(SC) <br /> a leak path between the manhole cover riser,dual ports for both a fill and vapor "plumber's plug"design. The Rainflght <br /> and spill bucket mounting ring.The need riser,and triple and quad ports for multi- cover features a finger-grip lifting facility <br /> for supplemental sealants is eliminated. ple fill and vapor risers. Vapor ports can and an integral seal.The sealable cover <br /> •Contractor-Friendly Installation- be supplied with or without containment features a cam-operated mechanism <br /> Studded mounting ring simply bolts buckets. that expands the-seal against the vertical <br /> together inside the spill containment Port Configurations-Standard port wall of the mounting ring. Both of these <br /> bucket. No need to align bolt holes in locations match the popular riser spat- water-shedding covers are protected by <br /> the manhole cover. ings(12", 14", 16"or 24")and bung con- raised mounting rings.A below-grade <br /> figurations on underground storage (BG)option is available which provides <br /> the manhole and spill buckke <br /> <►Raintight Service-Bunae t mounting gaskets on tanks. Custom port locations are easily watertight underground containment <br /> rings help prevent contamination of thee accommodated. vessels while maintaining anon-water- <br /> tight flush manhole cover surface. <br /> sump area from surface water intrusion. ►Monitoring Ports- Bolt-down,gasketed Fastener Options-Two types of <br /> •Highway 20 Load Rating-The rugged monitoring parts can be incorporated into fasteners are available to secure <br /> diamond plate steel manhole covers,as the manhole cover to provide observation the manhole lid and monitoring port <br /> access to the sump without removing the <br /> well as the cast iron (RT)or aluminum entire cover.Standard port diameter is 5" to mounfing rings.Standard are <br /> (SC)spill container covers meet H2O (13 cm)with larger ports available upon /18"-18 hex head bolts. Optional are <br /> Load Rating requirements. request. POMECO/OPW Roto-Lock Fasteners. <br /> *Spill Container and Manhole Positive The POMECO/OPW Roto-Lock <br /> I.D.System-Special recesses cast into , Manhole Cover Sizes-Standard bolt- system enables a secure,watertight <br /> spill container covers and machined into down manhole cover diameters of 30" connection without the need to locate <br /> manhole lids allow"Peel&Stick"tags to (76 cm), 37"(94 cm),42" (107 cm),and threaded bolt holes on the mounting ring................... <br /> be attached to the lids. Matchingbucket 48"(122 cm)allow ample access to the w <br /> sump area. Provision for a -13 lifting Custom Multi-Port Manholes-Contact <br /> tags can be affixed to the inside of the eyebolt is provided on 42"and 48"mod- your POMECO/OPW representative, <br /> spill container to prevent covers from els. Heavy-duty reinforced lid options are a Powder Coated Rings&Covers- <br /> ( .;w;.`ting switched. also available. Available upon request. <br /> CARB Certified-311 Series Approval ♦Spill Container Cover Options- <br /> Letter#93-25,500 Series EVR Approved Standard spill container options include <br /> Letter f192-12.511 and 611 Series Approval the patented POMECOIOPW dam and <br /> Letter <br /> Multi-Port Manhole Water Shroud System Option* <br /> .................... ... <br /> The OPW/POMECO Multi-Port Manhole Water Shroud (MPWS)system is designed to completely isolate surface water and condensa- <br /> tion from the Tank Sump.The MPWS features an injection molded fiberglass Water Shroud lid that mates to a standard tank sump top <br /> hat reducer. Shroud Boots isolate the spill container buckets using stainless steel band clamps,which provide a tight seal between the <br /> water shroud top hat and the underside of the spill container mounting rings.A 6"Sump Inspection Port is provided on each FRP <br /> Cover, allowing full inspection access through the Multi-Port Gauge Port.The OPW/POMECO Water Shroud system is available in 33" <br /> and 36"models.The MPWS Water Shroud is sold separately. <br /> 'Only available with new 500 Series Multi-Ports. <br /> � er <br /> M <br /> Shroud Boots — Vinyl Plastisol Sump Inspect Port (SIP) — Vapor FRP Cover— Injection Molded <br /> Tight, Clear ABS Construction Fiberglass Cover <br /> Inspection Port <br />
The URL can be used to link to this page
Your browser does not support the video tag.