My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2008 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
707
>
2300 - Underground Storage Tank Program
>
PR0505735
>
COMPLIANCE INFO 2008 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2023 3:29:34 PM
Creation date
11/8/2018 9:53:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008 - 2015
RECORD_ID
PR0505735
PE
2361
FACILITY_ID
FA0006972
FACILITY_NAME
TSI TRANS SYSTEM INC
STREET_NUMBER
707
Direction
E
STREET_NAME
ROTH
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231-9774
APN
19332008
CURRENT_STATUS
01
SITE_LOCATION
707 E ROTH RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\R\ROTH\707\PR0505735\COMPLIANCE INFORMATION 2008 - 2015.PDF
QuestysFileName
COMPLIANCE INFORMATION 2008 - 2015
QuestysRecordDate
6/29/2018 3:29:31 PM
QuestysRecordID
3930717
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
342
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> All installation and testing shall be in compliance with manufacturer's instructions, section <br /> 2635 and section 2636 of CCR and Chapter 6.7 of the Health and Safety Code as amended <br /> and effective July 1, 2003. <br /> 9 All piping must slope and be able to drain to a containment sump with an audible/visual alarm. <br /> 1 . All connections (shraeder valves) on the piping must be turned down. <br /> 11. An integrity test must be performed in accordance with the manufacturer's guidelines for the <br /> tank and the piping once the site is in operating condition (once concrete is poured) and before <br /> the final inspection. A hard copy of the results must be submitted to this office prior to <br /> operation. <br /> 12.All secondary containment must be constructed to prevent water intrusion. <br /> 13.All secondary containment systems must be continuously monitored. <br /> 14. The lake test for the secondary containment testing must be performed above the highest <br /> penetration level. <br /> 15. All Blueline test boots must be removed after testing is complete. <br /> 13. All metal components in direct contact with the backfill such as flexible connectors, swing <br /> joints, fittings, and pumps shall be protected from corrosion. <br /> 1 . Contact Muniappa Naidu, REHS at (209) 468-3439 for the following inspections: <br /> a. Primary piping Soap test. <br /> b. Secondary piping Soap test. <br /> c. Slope for piping. <br /> d. Lake test for the sumps and under dispenser containment. <br /> e. Cathodic protection on all metal components. <br /> f. Final monitoring certification. <br /> 1 . A "Certificate of Compliance for Underground Storage Tank Installation Form C" shall be <br /> submitted by the owner or the owners' agent [pursuant to California Code of Regulation (CCR) <br /> 2635(d)] before this install will be considered complete by EHD. <br /> 1 . No gasoline, diesel, or other hazardous material or waste can enter the sewer or storm water <br /> system. If it does, it will be considered illegal hazardous waste disposal. <br /> 2 . Prior to scheduling a final inspection facility must submit the following: <br /> • An accurate and drawn-to scale-as-built plan. <br /> • A current Monitoring and Response Plan. <br /> 2 . All appointments must be scheduled 48 hours in advance. <br /> 2 . Permit expires 180 days from date of approval. Note: If an extension to the expiration date is <br /> required, a written request must be submitted to this office prior to the expiration date <br /> Thank you, <br /> Wl wwaw Af -o(/I <br /> Muniappa Naidu, REHS <br /> San Joaquin County <br /> Envir nmental Health Department <br /> Page 2 of 2 <br />