My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1987-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SHAW
>
1113
>
2300 - Underground Storage Tank Program
>
PR0231728
>
COMPLIANCE INFO 1987-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2024 2:54:34 PM
Creation date
11/8/2018 9:53:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1987-2015
RECORD_ID
PR0231728
PE
2361
FACILITY_ID
FA0003565
FACILITY_NAME
UNIVERSAL SWEEPINGS SERVICES
STREET_NUMBER
1113
STREET_NAME
SHAW
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
14327042
CURRENT_STATUS
02
SITE_LOCATION
1113 SHAW RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\S\SHAW\1113\PR0231728\COMPLIANCE INFO 1987-2015.PDF
QuestysFileName
COMPLIANCE INFO 1987-2015
QuestysRecordDate
5/31/2017 3:41:00 PM
QuestysRecordID
3403671
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
218
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br /> 23 3 <br /> t R T TANK RECAILT-a2a <br /> (3) Other monitoring methods may be used in lieu of the requirement in <br /> subdivision(2)if it is demonstrated to the satisfaction of the local agen <br /> that the alternate method is as effective as the methods otherwise requ' ed <br /> by this section. A continuous monitoring system as described in <br /> subdivision(1), which shuts down the pump in addition to activating the <br /> alarm system, satisfies the automatic line leak detector requirement of <br /> subdivision(2). <br /> (4) Monitoring shall be conducted on all underground pressurized piping ith <br /> / secondary containment at least annually at a pressure designated by the <br /> equipment manufacturer, provided that the method is capable of dete ing a <br /> minimum release equivalent to 0.1 gallon per hour defined at 150 perc nt <br /> of the normal operating pressure of the product piping system at the test <br /> pressure with at least a 95 percent probability of detection and not more <br /> than a 5 percent probability of false alarm. This requirement is waived if <br /> J a <br /> &3 the criteria in subsection(g) of this section are met. <br /> (g) Underground pressurized piping which meets all of the following requiremeni s <br /> satisfies the annual tightness test requirement specified in subsection (f)(4): <br /> ✓(1) The secondary containment system is equipped with a continuous <br /> monitoring system. The leak detection device may be located at the pump <br /> sump if the piping slopes back to this point. <br /> vl(2) A continuous monitoring system is connected to an audible and visual <br /> alarm system and the pumping system. <br /> L/3) A continuous monitor shuts down the pump and activates the alarm ystem <br /> when a release is detected. <br /> VIM The pumping system shuts down automatically if the continuous <br /> monitoring system fails or is disconnected. <br /> (5) The requirements of subdivisions(3) and (4) do not apply to an em gency <br /> generator, provided the monitoring system is checked at least daily. <br /> Authority: Health and Safety Code 25299.3 and 25299.7 <br /> Reference: Health and Safety Code 25281, 25291, 25299; <br /> 40 CFR 280.20, 80.40-280.45 <br /> 31 <br />