Laserfiche WebLink
C,AMP0 0 <br /> LSOCC-120 ELECTRONIC AUTOMATIC LINE LEAK DETECTOR <br /> ALARMS WITHIN SECONDS WHEN PRODUCT LINE LEAK OCCURS <br /> i <br /> 0 <br /> 'I'LL 11 <br /> m tar <br /> LM DeTaciton <br /> �' ura; <br /> y. <br /> ' 1�1�ti,lGitpr��t�t7 t <br /> yy ri <br /> • ,Ir• <br /> FEATURES: <br /> • THIRD PARTY TESTED - In accordance with the EPA requirements, a nationally recognized testing laboratory <br /> conducted tests which thoroughly tested the LS300-120 under real world conditions. <br /> • LEAK TEST-A leak test is performed each time the submersible pump is shutdown . If a leak is detected an alarm <br /> is activated with audio, visual and remote signaling capabilities. <br /> • FLEXIBILITY - The LS300-120 test parameters are field adjustable to allow compensation for a particular site's <br /> characteristics.Thus avoiding the false alarms that are so familiar with mechanical line leak detectors. <br /> • FALSE ALARM-If a false alarm is sounded due to a faulty valve or debris in the piping system the LS300-120 will <br /> not disrupt product sales by preventing continued operation of the system. <br /> •AUTO CLEARING-Automatically resets alarm,if subsequent test shows no leak.Avoids the need for the operator <br /> to manually reset alarms due to transient conditions,such as an improper seating of the turbine pump check valve. <br /> •EASY TO INSTALL-Detectorcan be mounted on dispenser top,utilizes existing AC power and a transducer screws <br /> into existng port of the dispensefs fire valve.No special tools or training required. <br /> OPERATION: <br /> The Model LS300-120 is designed to perform a leak test at the end of each pumping cycle by monitoring the product <br /> line pressure decay time immediately following the pump shut down.The test compares the expected line pressure decay <br /> with the actual pressure decay.The leak test is initiated when the line pressure signaled to the controller by the transducer <br /> drops below the high threshold,the test lasts 10 to 150 seconds (selectable).If the line pressure decays to below the low <br /> pressure threshold prior to the conclusion of the test period,a leak condition is indicated and the alarm is activated.An <br /> on-board relay output is activated with the alarm for the purpose of remote signaling and/or submersible pump <br /> deactivation. If a subsequent test results in a no leak condition then the alarm will self cancel . An alarm may also be <br /> cancelled by depressing the Test/Reset button.An on-demand self test function provides verification of the controller's <br /> operating status. Front panel indicators give the current status of the LS300-120 at every point of its'operational cycle. <br /> CAMPO/ MILLER Post Office Box 1809, Porterville,CA 93258-1809. (209)781-6862. FAX(209)781-7304 <br /> RM 8 7191 <br />