My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2015 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
15250
>
2300 - Underground Storage Tank Program
>
PR0537919
>
COMPLIANCE INFO_2015 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 2:20:42 PM
Creation date
11/8/2018 9:54:20 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015 - 2018
RECORD_ID
PR0537919
PE
2351
FACILITY_ID
FA0021886
FACILITY_NAME
Love's Travel Stop #538
STREET_NUMBER
15250
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
RD
City
Lodi
Zip
95242
CURRENT_STATUS
01
SITE_LOCATION
15250 N THORNTON RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\THORNTON\15250\PR0537919\COMPLIANCE INFO 2015 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2015 - PRESENT
QuestysRecordDate
12/7/2017 11:45:50 PM
QuestysRecordID
3743012
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
201
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Date: <br />April 12, 2018 <br /> Facility Address: <br /> 15250 N THORNTON RD, LODI <br /> Facility Name: <br /> LOVES TRAVEL STOP #538 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 305 HSC 25290.1(e) VPH monitoring of the interstitial spaces of the UST system is not maintained. <br />A work order from B.Z. Maintenance dated 10/23/17 indicated that brine was added to dispenser 9/10, and that <br />there is a possible "leak into ground." On the 5/12/17 designated operator monthly inspection report, the work order <br />by B.Z. Maintenance dated 4/26/17, indicated that brine was added to dispenser 3/4, but no additional follow up was <br />documented. The sensors monitoring the liquid level in the interstitial space shall be maintained so that a breach in <br />the primary or secondary containment is detected before the hazardous substance is released into the environment. <br />Correct immediately by having a properly licensed, trained, and certified contractor investigate the UDC's and obtain <br />a permit within one business day from the EHD if necessary. <br />This is a minor violation. <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br />The UDC 15/16 brine sensor was located with insufficient brine levels. The sensors monitoring the liquid level in the <br />interstitial space shall be maintained so that a breach in the primary or secondary containment is detected before <br />the hazardous substance is released into the environment. Correct immediately by having a properly licensed, <br />trained, and certified contractor investigate the components with a functional component and obtain a permit within <br />one business day from the EHD if necessary. <br />This is a Class II violation. <br /> 316 HSC 25290.1(c3), 25290.2(c3) Secondary containment not constructed to prevent water intrusion (after Jul 2003). <br />Water was found in the 91 fill sump. Secondary containment shall be constructed to prevent any water intrusion into <br />the system by precipitation, infiltration, or surface runoff. Immediately remove this liquid, make a hazardous waste <br />determination per Title 22 hazardous waste regulations, and manage accordingly. Immediately contact a properly <br />licensed, trained, and certified contractor to address the water intrusion into the 91 fill sump under permit and <br />inspection of the EHD. <br />This is a minor violation. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork within 30 days of receipt of this report. <br />Note: Vacuum communication was not tested in the vent sumps, or dispensers. This testing will need to be <br />completed by the end of the month to complete the monitoring system certification. This inspection will be <br />billable. <br />Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br />documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br />Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br />applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br />Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br />Page 4 of 5 <br />FA0021886 PR0537919 SC001 04/12/2018 <br />EHD 23-01 Rev. 10/31/2017 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjcehd.com
The URL can be used to link to this page