My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2003 - 2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
8606
>
2300 - Underground Storage Tank Program
>
PR0232261
>
COMPLIANCE INFO 2003 - 2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 1:10:35 PM
Creation date
11/8/2018 9:54:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003 - 2006
RECORD_ID
PR0232261
PE
2361
FACILITY_ID
FA0002590
FACILITY_NAME
THORNTON 76
STREET_NUMBER
8606
STREET_NAME
THORNTON
STREET_TYPE
RD
City
STOCKTON
Zip
95209
APN
07242019
CURRENT_STATUS
01
SITE_LOCATION
8606 THORNTON RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\THORNTON\8606\PR0232261\COMPLIANCE INFO 2003 - 2006.PDF
QuestysFileName
COMPLIANCE INFO 2003 - 2006
QuestysRecordDate
2/27/2018 6:46:39 PM
QuestysRecordID
3808828
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
302
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Triangle Environmental, Inc. <br /> UST MONITOR CER TITICA TION S UMMA R Y SHEE T <br /> Client: <br /> Phillips 66 Company <br /> 1500 North Priest Drive Phillips Facility # 08671 <br /> Tempe, AZ 85281 <br /> Facility: 2708671 Test Date: 6/ 6/02 <br /> Phillips Facility # 08671 Work#: 12901008 <br /> 8606 THORNTON RD County: SAN JOAQUIN <br /> Cross Street: DAVIS <br /> STOCKTON, CA 95209 <br /> Monitor model: VEEDER-ROOT TLS-350 <br /> Serial#: 80448140605001 Certification Result: PASS <br /> Sensor Type: Quantity: Result: <br /> Tank Annular : 3 PASS Annular Type: DRY <br /> Waste Oil Annular : 0 N/A Audible Alarm? Yes <br /> Waste Oil Sump: 0 N/A Visual Alarm? Yes <br /> Vadose Wells : 0 N/A Fail Safe? Yes <br /> Line Pressure : 0 N/A Positive Shut-off? Yes <br /> Turbine Sump : 3 PASS Gauge Only Result: PASS <br /> Line Trench : 0 N/A ATG Monthly? No <br /> Fill Sump : 0 N/A ATG CSLD? No <br /> Comments: <br /> This certifies that the monitor and sensors,as listed above,are operational and calibrated per the <br /> manufacturer's specification. <br /> Inspected By: <br /> Tom Corcoran /'� <br />
The URL can be used to link to this page
Your browser does not support the video tag.