My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1998-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3775
>
2300 - Underground Storage Tank Program
>
PR0231418
>
COMPLIANCE INFO 1998-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:03 PM
Creation date
11/8/2018 9:55:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2006
RECORD_ID
PR0231418
PE
2361
FACILITY_ID
FA0003715
FACILITY_NAME
Tracy Blvd Chevron
STREET_NUMBER
3775
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
3775 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\TRACY\3775\PR0231418\COMPLIANCE INFO\COMPLIANCE INFO 1998-2006.PDF
QuestysFileName
COMPLIANCE INFO 1998-2006
QuestysRecordDate
5/25/2016 9:55:35 PM
QuestysRecordID
3092689
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
386
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page of I <br /> 7.UNDER-DISPENSER CONTAINMENT(UDC) TESTING <br /> Test Method Developed By: UDC Manufacturer ❑ Industry Standard N Professional Engineer ❑ <br /> Other(Specify) <br /> Test Method Used: Pressure ❑ Vacuum ❑ Hydrostatic N <br /> Other(Specify) <br /> Test Equipment Used: Wayne Perry Inc. See Attached Testing Results Equipment Resolution: .00007 <br /> Under-Dispenser Containment Number Below <br /> UDC Manufacturer: <br /> UDC Material: u <br /> UDC Depth: Z.5," z lC 75' 21" 7-S- " <br /> Height from UDC Bottom to Top <br /> of Highest Piping Penetration: 5 " 5 5 " 5 <br /> Height from UDC Bottom to <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to <br /> Portion of UDC Tested' 2"Above Highest 2"Above Highest 2"Above Highest 2"Above Highest <br /> Penetration Penetration Penetration Penetration <br /> Does turbine shut down when ❑Yes❑ No NAN ❑ Yes❑ No NAN ❑ Yes❑ No NAN ❑Yes❑ No NAM <br /> UDC sensor detects liquid. <br /> Turbine shutdown response time ❑Yes❑ No NAM ❑Yes❑ No NAM ❑Yes❑ No NAM ❑ Yes❑ No NAM <br /> Is system programmed for fail- ❑ Yes❑ No NAM ❑Yes❑ No NAN ❑Yes❑ No NAN ❑Yes❑ No NAM <br /> safe shutdown?` <br /> Was fail-safe verified to be ❑Yes❑ No NAM ❑Yes❑ No NAN ❑ Yes❑ No NAM ❑Yes❑ No NAM <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and 15 Minutes 15 Minutes 15 Minutes 15 Minutes <br /> starting test <br /> Test Start Time: 7 7:, 5.z -1 . 2OL ?:IS 2 <br /> Initial Reading(RO: J C9SJ r925D zP>s7Z E 3EY9 I.A91r1� <br /> Test End Time: 3:0 3,03 Y.,C7 90 37V/ 4!Iv7 <br /> Final Reading(RF): J9G 3 A40?7S3 % 7.-V' 7. 2.13 rV <br /> Test Duration: 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min <br /> Change inReading(RF-Rt): oa000 .ocOS/ coal _GClY_T .e'oono,ococo <br /> Pass/Fail Threshold or Criteria: -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 <br /> Test Result: lR Pass ® .Pass _W Pass R Pass IN Puss N Pass ❑ Pass ❑ Pass <br /> ❑ Fail ❑ Fail ❑ Fail 1 ❑. Fail ❑ Fail ❑ Fail ❑ .Fail ❑ Fail <br /> Was sensor removed for testing? Gd Yes❑ No NA❑ ® Yes❑ No NA❑ ® Yes❑ No NAE] ® Yes❑ No NAE] <br /> Was sensor properly replaced and M Yes[1 No NA❑ ® Yes❑ No NA❑ ® Yes❑ No NAD ® Yes❑ No NA❑ <br /> verified functional after testin ? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up forfailed tests) <br /> Chevron#98264 <br /> 3775 N. Tracey Blvd. <br /> Tracey, CA 95376 <br /> N05207-SB 989 Testing <br />