Laserfiche WebLink
Page of I <br /> 7.UNDER-DISPENSER CONTAINMENT(UDC) TESTING <br /> Test Method Developed By: UDC Manufacturer ❑ Industry Standard N Professional Engineer ❑ <br /> Other(Specify) <br /> Test Method Used: Pressure ❑ Vacuum ❑ Hydrostatic N <br /> Other(Specify) <br /> Test Equipment Used: Wayne Perry Inc. See Attached Testing Results Equipment Resolution: .00007 <br /> Under-Dispenser Containment Number Below <br /> UDC Manufacturer: <br /> UDC Material: u <br /> UDC Depth: Z.5," z lC 75' 21" 7-S- " <br /> Height from UDC Bottom to Top <br /> of Highest Piping Penetration: 5 " 5 5 " 5 <br /> Height from UDC Bottom to <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to <br /> Portion of UDC Tested' 2"Above Highest 2"Above Highest 2"Above Highest 2"Above Highest <br /> Penetration Penetration Penetration Penetration <br /> Does turbine shut down when ❑Yes❑ No NAN ❑ Yes❑ No NAN ❑ Yes❑ No NAN ❑Yes❑ No NAM <br /> UDC sensor detects liquid. <br /> Turbine shutdown response time ❑Yes❑ No NAM ❑Yes❑ No NAM ❑Yes❑ No NAM ❑ Yes❑ No NAM <br /> Is system programmed for fail- ❑ Yes❑ No NAM ❑Yes❑ No NAN ❑Yes❑ No NAN ❑Yes❑ No NAM <br /> safe shutdown?` <br /> Was fail-safe verified to be ❑Yes❑ No NAM ❑Yes❑ No NAN ❑ Yes❑ No NAM ❑Yes❑ No NAM <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and 15 Minutes 15 Minutes 15 Minutes 15 Minutes <br /> starting test <br /> Test Start Time: 7 7:, 5.z -1 . 2OL ?:IS 2 <br /> Initial Reading(RO: J C9SJ r925D zP>s7Z E 3EY9 I.A91r1� <br /> Test End Time: 3:0 3,03 Y.,C7 90 37V/ 4!Iv7 <br /> Final Reading(RF): J9G 3 A40?7S3 % 7.-V' 7. 2.13 rV <br /> Test Duration: 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min <br /> Change inReading(RF-Rt): oa000 .ocOS/ coal _GClY_T .e'oono,ococo <br /> Pass/Fail Threshold or Criteria: -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 <br /> Test Result: lR Pass ® .Pass _W Pass R Pass IN Puss N Pass ❑ Pass ❑ Pass <br /> ❑ Fail ❑ Fail ❑ Fail 1 ❑. Fail ❑ Fail ❑ Fail ❑ .Fail ❑ Fail <br /> Was sensor removed for testing? Gd Yes❑ No NA❑ ® Yes❑ No NA❑ ® Yes❑ No NAE] ® Yes❑ No NAE] <br /> Was sensor properly replaced and M Yes[1 No NA❑ ® Yes❑ No NA❑ ® Yes❑ No NAD ® Yes❑ No NA❑ <br /> verified functional after testin ? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up forfailed tests) <br /> Chevron#98264 <br /> 3775 N. Tracey Blvd. <br /> Tracey, CA 95376 <br /> N05207-SB 989 Testing <br />