My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2007 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TURNER
>
2500
>
2300 - Underground Storage Tank Program
>
PR0232507
>
COMPLIANCE INFO 2007 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/28/2023 12:00:24 PM
Creation date
11/8/2018 9:56:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007 - 2015
RECORD_ID
PR0232507
PE
2361
FACILITY_ID
FA0003846
FACILITY_NAME
Verizon Business: LDIKCA
STREET_NUMBER
2500
Direction
W
STREET_NAME
TURNER
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
029-030-39
CURRENT_STATUS
01
SITE_LOCATION
2500 W Turner Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\TURNER\2500\PR0232507\COMPLIANCE INFO 2007 - 2015.pdf
QuestysFileName
COMPLIANCE INFO 2007 - 2015
QuestysRecordDate
9/9/2016 5:33:19 PM
QuestysRecordID
3186119
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
362
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 <br /> Page 4 of 7 <br /> 6.PIPING SUMP TESTING <br /> Test Method Developed By: ❑Sump Manufacturer 19 Industry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Uses: ❑Pressure ❑Vacuum 0 Hydrostatic <br /> ❑Other eci <br /> Test Equipment Used: INCON TS-STS E=quipment Resolution:0.001" <br /> M = Sump# TURBINFW Sump# TURBINEd Sump# Sump# <br /> Sump Diameter: 36" 36" <br /> Sump Depth: 48" 48" <br /> Sump Material: FIBERGLASS FIBERGLASS <br /> Height from Tank Top to Highest 19" 18" <br /> Piping Penetration: <br /> Height from Tank Top to Lowest 15" 14" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: GOOD GOOD <br /> Portion of Sump Tested' 21" 21" <br /> Does turbine shut down when <br /> stunp sensor detects either product NA NA <br /> or water? <br /> Turbine shutdown response time 21 NA NA <br /> Is system programmed for fail-safe NA NA <br /> shutdowm?• <br /> Was fail-safe verified to be NA NA <br /> operational?* <br /> Wait time between applying <br /> pressurc/vacuum/water and starting 30 MIN. 30 MIN. <br /> test: <br /> Test Start Time: 11;35 AM/11:52 AM It:35 AM/11:52 AM <br /> Initial Reading(111): 7.5550"17.5549" 6.7227"16.7224" <br /> Test End Time: 11.50 ANV12:07 PM 11:50 AM112:07 PM <br /> Final Reading(RF): 7,5549"n.5549" 6.7224"16.7222" <br /> Test Duration: 2X15 MIN. 2Xt5 MIN. <br /> Change in Reading(RF-RI): 0 -0.0002" <br /> Pass/Fail"Threshold or Criteria: 0.002" 0.002" <br /> Test Result: PASS PASS <br /> Was sensor remove for testing? YES YES <br /> Was sensor properly replaced after YES YES <br /> testing? <br /> Comments-(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> If the testing method does not test the entire sump,specify how much of the sump was tested. Methods not testing the <br /> entire sump should only be used if the monitoring system provides fail-safe shutdown.(See SWRCB LG-160) <br /> 7 With the submersible pump running,place the sensor in product(discriminating sensors should be placed in water).The time <br /> between placing the sensor in product and the turbine shutting down is the response time.This should be done if the secondary <br /> containment method used does not test the entire volume of the sump. <br /> 0 This information is not needed if the entire sump is tested. <br /> Revision: <br />
The URL can be used to link to this page
Your browser does not support the video tag.