My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2007 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TURNER
>
2500
>
2300 - Underground Storage Tank Program
>
PR0232507
>
COMPLIANCE INFO 2007 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/28/2023 12:00:24 PM
Creation date
11/8/2018 9:56:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007 - 2015
RECORD_ID
PR0232507
PE
2361
FACILITY_ID
FA0003846
FACILITY_NAME
Verizon Business: LDIKCA
STREET_NUMBER
2500
Direction
W
STREET_NAME
TURNER
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
029-030-39
CURRENT_STATUS
01
SITE_LOCATION
2500 W Turner Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\TURNER\2500\PR0232507\COMPLIANCE INFO 2007 - 2015.pdf
QuestysFileName
COMPLIANCE INFO 2007 - 2015
QuestysRecordDate
9/9/2016 5:33:19 PM
QuestysRecordID
3186119
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
362
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
... -W <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209) 468-3420 Fax: (209) 468-3433 Web:www.sogov.org/ehd <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Faality Verizon Business Fatality 2500 WTurner Rd. Lodi CA 95242 Date: 1Dfp <br /> ed <br /> Nameme. Address: WIns. Apr 10, 2013 <br /> Date: <br /> VIOLATIONS <br /> # Ci C2 M Code 5ettlOrl HSC=CA Health and SafetyCode,CFR=Code of Federal Regulations <br /> C 1=Class 1 violation,C2-Class 2%notation.M=Minor violation <br /> Non-Pressurized Piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1,1984) imi) <br /> 703 CCR 2643(d) Tnennial line test for conventional suction piping not performed(pre-January 1, 1984) (Mi) <br /> Other Violations <br /> 999 1 j0ther: see attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> On site to conduct a routine inspection and witness the annual monitoring system certification testing. <br /> 109. Annual monitoring system certification, leak detector testing, and spill container testing was <br /> performed on May 17, 2012, and a test report was not received within thirty days by the EHD. The test <br /> report was received on July 19, 2012. A copy of the test report must be submitted within 30 days of the <br /> tests. Take the necessary precautions to ensure that a copy of the test report is submitted to the EHD <br /> within thirty days of the test. <br /> 113. A new designated operator was hired on September 11, 2012, and notification was not provided to <br /> the EHD within 30 days of the change. Any changes shall be reported to the EHD within 30 days. Submit <br /> notification to the EHD identifying all the designated operators for this facility by May 10, 2013. <br /> 201. The sensor#2 in the north turbine sump alarmed on December 4, 2012. The designated operator <br /> did not document this alarm on the monthly designated operator report and the facility alarm lag was not <br /> on site. Thomas Penry explained that an inventory print out is placed into the "Weekly Monitoring UST <br /> Binder" and that any alarm print outs would also be placed into this same binder. These records shall be <br /> kept on site for at least 3 years_ Immediately locate and maintain the facility alarm log on site and submit <br /> copies to the EHD by May 10, 2013. <br /> 204. The designated operator failed to document all the alarms from the attached alarm history on the <br /> December 7, 2012, designated operator monthly inspection report and failed to check that they were <br /> responded to appropriately. The missing alarm includes: sensor#2 north turbine sump alarm. During the <br /> monthly inspection, the designated operator shall review the alarm history for the previous month, check <br /> that each alarm was documented and responded to appropriately, and attach a copy of the alarm history <br /> with documentation taken in response to any alarms to the monthly report. Ensure that designated <br /> operators performing monthly inspections at this facility are including all of the required information on <br /> the reports. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS <br /> LSUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Inspedac � Received XVII <br /> Tette <br /> EHD 23-02 Rev 04119/12 Page 3 DST INSPECTION REPORT <br />