PE
2361
FACILITY_ID
FA0003846
FACILITY_NAME
Verizon Business: LDIKCA
STREET_NUMBER
2500
Direction
W
STREET_NAME
TURNER
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
029-030-39
CURRENT_STATUS
01
SITE_LOCATION
2500 W Turner Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\TURNER\2500\PR0232507\COMPLIANCE INFO 2007 - 2015.pdf
QuestysFileName
COMPLIANCE INFO 2007 - 2015
QuestysRecordDate
9/9/2016 5:33:19 PM
QuestysRecordID
3186119
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
362
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONOPORING SYSTEM CERTIFrtATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cite& Chapter 6 7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be repared <br /> for each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank <br /> system owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 <br /> days of test date. <br /> A. General Information <br /> Facility Name: VZB-LDIKCA Bldg.No.: <br /> Site Address:2500 W. Turner Rd. City:Lodi Zip: 95242 <br /> Facility Contact Person: Jonathan Pakele Contact Phone No.: ( 916 ) 439-6042 <br /> Make/Model of Monitoring System:Pneumercator TMS-2000 Date of Testing/Servicing: 5 / 17 12 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced: <br /> Tank ID: UST Diesel Tank Tank ID: <br /> In-Tank Gauging Probe. Model: 4505-M-25 ❑In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: - ❑Annular Space or Vault Sensor. Model: <br /> (� Piping Sump 1 Trench Sensor(s). Model: 2) ❑Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector_ Model: ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: L❑Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor.Model: FLEcTRomc/NiEcnANmcAL ❑Tank Overfill/High-Level Sensor.Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: Tank ID: <br /> ❑ In-Tank Gauging Probe. Model: ❑In-Tank Gauging Probe. Model: <br /> ❑Annular Space or Vault Sensor. Model: ❑Annular Space or Vault Sensor. Model! <br /> ❑Piping Sump 1 Trench Sensor(s). Model: ❑Piping Sump/Trench Sensor(s). Model: <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor.Model: ❑Tank Overfill/High-Level Sensor.Model: <br /> d Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s).Model: ❑ Dispenser Containment Sensor(s).Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID• <br /> ❑ Dispenser Containment Sensor(s).Model: ❑Dispenser Containment Sensor(s).Model: <br /> ❑ Shear Valve(s)_ ❑Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> "If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is <br /> correct and a Plot Plan showing the layout of monitoring equipment.For any equipment capable f generating such reports,I have also <br /> attached a copy of the report; (check all that apply): 0 System set-up report; in stowe�o <br /> Technician Name(print): Paul McLane Signature: a do <br /> or <br /> Certification No.: 5238651-UT License No.: 703190 <br /> Testing Company Name: Sunwest Engineering Inc. Phone No.: 909 594-9850 <br /> Page 1 of 3 03/O] <br />