My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2007 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TURNER
>
2500
>
2300 - Underground Storage Tank Program
>
PR0232507
>
COMPLIANCE INFO 2007 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/28/2023 12:00:24 PM
Creation date
11/8/2018 9:56:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007 - 2015
RECORD_ID
PR0232507
PE
2361
FACILITY_ID
FA0003846
FACILITY_NAME
Verizon Business: LDIKCA
STREET_NUMBER
2500
Direction
W
STREET_NAME
TURNER
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
029-030-39
CURRENT_STATUS
01
SITE_LOCATION
2500 W Turner Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\TURNER\2500\PR0232507\COMPLIANCE INFO 2007 - 2015.pdf
QuestysFileName
COMPLIANCE INFO 2007 - 2015
QuestysRecordDate
9/9/2016 5:33:19 PM
QuestysRecordID
3186119
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
362
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1*111111W r..r <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www.s*,qov.org/ehd <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Name: FacilityVerizon Business Address: <br /> 2500 W. Turner Rd. Lodi CA 95242 Inspection Apr 9, 2014 <br /> Name: Address. Date: <br /> VIOLATIONS <br /> # I C1 I C2 M I Code Section HSC=CA Health and Safety Code;GFR=Code of Federal Regulations <br /> C1 =Class 1 violation;G2=Class 2 violation,M=Minor violation <br /> On Site Records(continued) <br /> 204 CCR 2715(c) Designated operator monthly inspection:(1)alarms not documented;(2-4)spill containers,UDCs,and sumps <br /> if necessary)not inspected; 5 required test dates not checked or noted; fi employee training not verified <br /> 205 CCR 2715(e) Designated operator monthly inspection reports not maintained on site for at least 12 months <br /> 206 CCR 27151 Designated operator employee training:(1)not performed;(2)not current for at least one employee on site; <br /> 3 log not ke t <br /> 207 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept <br /> Observations <br /> 301 HSC 25292.1 UST system is not operated to prevent unauthorized release,including spills and overfills <br /> 302 HSC 25291(b) UST monitoring system incapable of detecting leak from primary containment into secondary containment(MI) <br /> 303 X CCR 2631 UST monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity (M1) <br /> 304 CCR 2632(c)(2) Monitoring system is not present in the interstitial space of a double walled UST (M1) <br /> 305 CCR 2636(f)(1) Failed to maintain a continuous monitoring system for underground piping&UDCs that activates an (M1) <br /> audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br /> 306 CCR 2631(a) Primary containment is not product tight <br /> 307 HSC 252911 Secondary containment for UST system is not tight <br /> 308 CCR 2631 All releases in secondary piping do not flow to a collection sump <br /> 309 CCR 2636(a) Failed to have secondary containment for piping(includes conventional suction piping) (M2) <br /> 310 HSC 25291(e) Water in 21 containment not removed,analyzed&properly disposed of <br /> 311 CCR 2636(f}(2) Line leak detectors)not installed or failed to detect a 3-gallon per hour leak at 10 psi (Mi) <br /> 312 CCR 2635(b) No spill container or overfill prevention system installed (M2) <br /> 313 CCR 2635(b}(1) Spill container failed to contain a minimum capacity of five gallons,or failed to provide a means to keep (M2) <br /> the spill container empty <br /> 314 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfiil requirements (M2) <br /> 315 HSC 25299(f)(2) Tampering with or disabling leak detection devices or alarms <br /> 316 CCR 2631.1(a) UST system is not compatible with the substance stored <br /> 317 HSC 25298(a) Illegally abandoned UST system <br /> AB 1702(2003-2004) HSC 25290.2(installed between 07/01/03 and 06130104) <br /> VPH Systems HSC 25290.1 installed on or after 07/01/04 <br /> Compatibility and permeability requirements:(a)UST system is not compatible with the substance stored;(b) <br /> 401 CCR 2631.1 results of the compatibility and permeability testing requirements listed in subsections CCR 21 and(d) <br /> for a UST system installed after July 1,2004,were not submitted <br /> 402 HSC 25290.1(c)(1) Primary containment not liquid or vapor tight <br /> HSC 25290.2(c)(1) <br /> 403 HSC 25291 Secondary containment not liquid or vapor tight <br /> HSC 25290.2(c 2 <br /> 404 HSC 252913) Secondary containment not constructed to prevent water intrusion <br /> HSC 25290.2(c)(3) <br /> 405 NSC 25290.1(d) Monitoring system not maintained to detect water intrusion into the secondary containment,or the entry of <br /> HSC 25290.2(d) liquid or vapor from the primary containment into the secondary containment <br /> 406 HSC 25290.1(e) Interstitial liquid measurement method,constant vacuum,or constant pressure in the interstitial space of the <br /> UST system not maintained <br /> 407 HSC 25290.10) UST system not tested by one of the following methods prior to use:(1)Enhanced leak detection;(2)inert gas <br /> HSC 25290.2(i) pressure test approved by SWRCB; 3 test method deemedequivalent uivalent to 1 or 2 by the SWRCB <br /> Emergency Generator Systems <br /> 501 CCR 2636(1 Emergency generator monitoring system not checked daily or log not kept if no leak detector {Mil <br /> 502 HSC 25281.5(b)(3) Unburied fuel piping not visually inspected at least monthly or log not kept {Mt] <br /> USTs in a Vault <br /> 601 HSC 25283.5(a)(1) All exterior surfaces of the tank and connected piping cannot be directly viewed <br /> 602 HSC 25283.5(a)(2) Structure that the UST is located in does not provide for secondary containment <br /> 603 HSC 25283.5(a)(3) Failed to conduct weekly UST inspections or maintain a log of weekly inspections <br /> 604 HSC 25283 5(a)(5) UST installed after July 1,2003,does not meet or exceed applicable sections of FISC 25291 <br /> Non-Pressurized Piping <br /> 701 CCR 2643(d) Daily monitoring of suction piping(pre-January 1, 1984)not performed (M1} <br /> inspecicr R etl BTitle. <br /> Aris Veloso (209) 468-3453 tW <br /> EHE 23-02 Rev 04122!13 Page 2 UST INSPECTION REPORT <br />