COMPLIANCE INFO 2007 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TURNER
>
2500
>
2300 - Underground Storage Tank Program
>
PR0232507
>
COMPLIANCE INFO 2007 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/28/2023 12:00:24 PM
Creation date
11/8/2018 9:56:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007 - 2015
RECORD_ID
PR0232507
PE
2361
FACILITY_ID
FA0003846
FACILITY_NAME
Verizon Business: LDIKCA
STREET_NUMBER
2500
Direction
W
STREET_NAME
TURNER
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
029-030-39
CURRENT_STATUS
01
SITE_LOCATION
2500 W Turner Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\TURNER\2500\PR0232507\COMPLIANCE INFO 2007 - 2015.pdf
QuestysFileName
COMPLIANCE INFO 2007 - 2015
QuestysRecordDate
9/9/2016 5:33:19 PM
QuestysRecordID
3186119
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
362
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209) 468-3433 Web:www.sidov.org/ehd <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br /> FacilityFacility Inspection <br /> Name: Verizon Business Address 2500 W. Turner Rd. Lodi CA 95242 pate Apr 9, 2014 <br /> VIOLATIONS <br /> # r_1 C2 M Code Section HSC=CA Health and Safe Code;CFR=Code of Federal Re ulatbns <br /> C1 =Class 1 violation;C2=Class 2 violation:M=Minor violation <br /> Non-Pressurized Piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1, 1984) (Mi) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1, 1984) (Mi) <br /> Other Violations <br /> 999 Other: See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> GLASS I,CLASS II, or MINOR-Notice to Comply) <br /> On site to conduct a routine inspection and witness the annual monitoring system certification testing. <br /> This revised inspection supersedes the initial inspection report dated 4-9-14. <br /> 104. Financial responsibility documents which list Verizon Business 2500 W. Turner Rd. Lodi, CA <br /> 95242 have not been submitted to the EHD. Current financial responsibility documents are required to <br /> be submitted annually. Our records indicate that financial responsibility documents which list Verizon <br /> Business 2500 W. Turner Rd. Lodi, Ca 95242 expired 12-1-12. The current copy received does not <br /> include Verizon Business 2500 W. Turner Rd. Lodi, CA 95242 in the attached list of insured facilities. <br /> Immediately submit an updated copy of the financial responsibility documents to the EHD which include <br /> Verizon Business 2500 W. Turner Rd. Lodi, CA 95242. Alternatively, log into CERS, upload the required <br /> information, and submit for review by the EHD. Complete by May 9, 2014. <br /> 108. Secondary containment testing was last performed on 5-14-10 and was completed on 9-10-13, <br /> four months past due. Secondary containment testing is required once every 36 months. Take all <br /> necessary precautions to ensure testing is performed in a timely manner. <br /> 109. The line test which is part of the annual monitoring system certification was scheduled to be <br /> performed on 5-24-13 and a test report has not been submitted to the EHD. A copy of the test report <br /> must be submitted within 30 days of these tests. Immediately submit a copy of the test report or <br /> schedule these tests and provide 48 hours notification to the EHD. <br /> 303. The south turbine sump sensor was located on the west side of the sump and not located to <br /> detect a leak at the earliest opportunity. Monitoring equipment shall be maintained to be able to detect a <br /> leak at the earliest possible opportunity. Immediately relocate this sensor to the lowest point of the east <br /> side of the south turbine sump which is where the product piping penetrates the sump wall. Do this so <br /> that if any fuel leaks into the product secondary piping, then the south turbine sump sensor would be <br /> able to detect the leak at the earliest opportunity. If the sensor must be rewired to reach the lowest point <br /> of the east side of the south turbine sump, contact a properly licensed, trained, and certified contractor to <br /> perform the repair under permit and inspection of the EHD. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Inspector Receiv y: Title) <br /> EHD 23-42 Rev 04/19/12 Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.