COMPLIANCE INFO_JUN 2016 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
930
>
2300 - Underground Storage Tank Program
>
PR0502817
>
COMPLIANCE INFO_JUN 2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2019 4:51:00 PM
Creation date
11/8/2018 9:58:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
JUN 2016 - 2018
RECORD_ID
PR0502817
PE
2361
FACILITY_ID
FA0005584
FACILITY_NAME
VALLEY PACIFIC LODI PLANT & CARDLOCK
STREET_NUMBER
930
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04905023
CURRENT_STATUS
01
SITE_LOCATION
930 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\V\VICTOR\930\PR0502817\COMPLIANCE INFO\COMPLIANCE INFO JUN 2016 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO JUN 2016 - PRESENT
QuestysRecordDate
9/13/2016 6:46:00 PM
QuestysRecordID
3135584
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page 5 of_7_ <br /> 7. UNDER-DISPENSER CONTAINMENT C TESTING <br /> Test Method Developed By: ❑UDC Manufacturer ® Industry Standard ❑Professional Engineer <br /> ❑ Other(Specify) <br /> Test Method Used: ❑ Pressure ❑Vacuum E Hydrostatic <br /> ❑ Other(Spec) <br /> Test Equipment Used: INCON SUMP TESTER Equipment Resolution: 0.002" <br /> 00000� UDC#1-2 UDC#3-4 UDC# UDC# <br /> UDC Manufacturer: Bravo Pan Bravo Pan <br /> UDC Material: Steel Steel <br /> UDC Depth: 12" 12" <br /> Height from UDC Bottom to Top 2 5" 2.5" <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to NIA N/A <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to Dry Dry ENVIRONMENTAL HEALTH <br /> testing: <br /> n <br /> Portion of UDC Tested 2"/Penetrations 2"/Penetrations F' " <br /> ?A ENT <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both ❑Yes LINO ®NA Elves ❑No ®NA []Yes ❑No ❑NA ❑Yes []No [INA <br /> product and water)?* <br /> Turbine shutdown response time N/A NIA <br /> Is system programmed for fail- <br /> safeshutdown? ❑Yes [--]No ❑NA [:]Yes []No ®NA ❑Yes ❑No ❑NA []Yes ❑No ❑NA <br /> Was fail-safe verified to be []Yes ❑No [INA ❑Yes <br /> operational? ❑No ®NA ❑Yes []No ❑NA ❑Yes ❑No ❑NA <br /> Wait time between applying <br /> pressure/vacuum/water and 10 min. 10 min. <br /> starting test <br /> Test Start Time: 11:05am 11:05am <br /> Initial Reading(R): 2.8635" 2.0797" <br /> Test End Time: 11:20am 11:20am <br /> Final Reading(Rr): 2.8628" 2.0801" <br /> Test Duration: 15 min. 10 min. <br /> Change in Reading(RF-Rj): -0.0007" +0.0004" <br /> Pass/Fail Threshold or Criteria: +/.0.002" +/-0.002" +/-0.002" +/-0.002" <br /> Test Result: ®Pass ❑Fail ®Pass ❑ Fail ❑ Pass ❑Fail ❑Pass ❑ Fail <br /> Was sensor removed for testing? ❑Yes ❑No ®NA Elves ❑No ®NA ❑Yes ❑No ❑NA Elves [ No ENA <br /> Was sensor properly replaced and <br /> verified functional after testing? Elves ❑No ®NA Elves []No ®NA ❑Yes []No ❑NA ❑Yes ❑No ❑NA <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> 1. All UDCs have chain and floats installed for primary leak detection.Verified proper functionality testing <br /> per manufacture guidelines and product shut-off @ shear valve when in leak position. <br /> ' If the entire depth of the UDC is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />